HVTest PDF1000 Manual Download Page 12

12

faulted area will do the next location detection according to dichotomy, in order
to quickly detect the specific fault grounded point. Assume that find ground
fault at A place, and not find at B place, we can determine the fault grounded
point is between A and B. According to feeder cables and equipment
connections, you can respectively detect the entrances of feeder cables, and
find fault branch, then further locate fault point.

The calipers can be used to measure current of bus bar and feeder cables;

its sensitivity is extremely high. Because of its high sensitivity, when testing it is
necessary that let the calipers firmly clamp the feeder cables, until obtain
stable measured data.

4. Signal output lead
Red lead connects to fault bus bar terminal, black lead connects to ground.

Red plug inserts into "L" terminal of signal generator, and the black inserts

into”

" terminal.

Fig. 3 Picture for signal output lead

V. Notes

1. The device is a precise instrument, when transport, use and store, it

should be handled with care to prevent violent vibrations or shock.

2. Signal source should be added to fault bus bar and ground.
3. The calipers can only clamp DC circuit, cannot clamp AC circuit.
4. When there is no obvious ground point on each branch circuit, please

check power supply part such as battery, charger and other parts.

5. During test, if not use please turn power off to extend battery life.

Red

Black

Red

Black

Summary of Contents for PDF1000

Page 1: ...You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may br...

Page 2: ...refully to avoid body injury and prevent the product or other relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified...

Page 3: ...t Before connecting please read the instruction manual to acquire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...5 Contents I Overview 6 II Principle 7 III Specifications 8 IV Structure and Function of Instrument 9 V Notes 12 Appendix 1 structural representation 14 Appendix 2 brief method introduction 15...

Page 6: ...system The DC system of power plant and transformer substation is the power supply for control protect signal and auto equipment the safe continuous running is very important to generate and supply p...

Page 7: ...ction under no power interruption no effect to system normal work strong anti jamming ability safe and reliable Waveform analysis inject one special cyclical voltage signal between DC bus bar and grou...

Page 8: ...t circuit output current 80mA Output terminal shock resistance capability 400V DC impulse Supply voltage AC220V 10 Voltage frequency 50Hz 5 Single chip Signal sampling analog to digital conversion Sig...

Page 9: ...2 5mA Display of receiver number 0 19 Dimension 210x100x32mm A jaw size 50mm B jaw size 7mm 9mm 3 Complete appliance Measured maximum ground resistance 300k Ground resistance measurement accuracy 0 4...

Page 10: ...cating having normal low frequency voltage output Signal output the port for signal output When using please insert output leads to output signal Access signal generator Insert signal output leads int...

Page 11: ...s for Signal receiver With calipers respectively clamp all main circuit that were associated with fault bus bar and then observe LCD display Use number 0 19 from low to high to indicate insulation val...

Page 12: ...at let the calipers firmly clamp the feeder cables until obtain stable measured data 4 Signal output lead Red lead connects to fault bus bar terminal black lead connects to ground Red plug inserts int...

Page 13: ...ow battery please replace the battery timely to improve measurement accuracy 7 Since the receiver has high sensitivity when testing please do not grasp it let the receiver in quiescent state so as not...

Page 14: ...14 Appendix 1 structural representation...

Page 15: ...generator 3 Insert the plug of the caliper with the input jack of the signal receiver 4 Turn on the power switch of the signal receiver 5 Strangulate the measured circuit using caliper 6 Begin to test...

Page 16: ...16...

Reviews: