background image

1

Dear Client

Thank you for Purchasing our

HTJL-V High Precision SF6 Gas Leak

Detectorr

. Please read the manual in detail prior to first use, which will

help you use the equipment skillfully.

Our aim is to improve and perfect the company's

products continually, so there may be slight differences

between your purchase equipment and its instruction

manual. You can find the changes in the appendix. Sorry for

the inconvenience. If you have further questions, welcome to contact

with our service department.

The input/output terminals and the test column may bring

voltage, when you plug/draw the test wire or power outlet, they

will cause electric spark. PLEASE CAUTION RISK OF

ELECTRICAL SHOCK!

Company Address:

T4

No. 41, High-tech 2 Road

East Lake High-tech Development Zone

Wuhan

Sales Hotline: 86-27- 87457960

After Service Hotline

:

86-27- 87459656

Fax: 86-27- 87803129

E-mail: [email protected]

Website: www.hvtest.cc

Summary of Contents for HTJL-V

Page 1: ...ual You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may...

Page 2: ...e In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid fire and personal injury Use P...

Page 3: ...ngs Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the product Avoid Touching Bare Circuit...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...5 Contents I General Guide 6 II Function Overview 7 III Device Operation 10 IV Soft Reminders 22...

Page 6: ...it carefully before use No official notice will be made upon any alternation of this manual 1 1 Applicable Range This device is applicable to the fast and accurate qualitative and quantitative measure...

Page 7: ...tage circuit breakers has been increasing by about 15 each year In the field of high pressure extra high pressure and ultra high pressure switches SF6 has become the only insulating and arc extinguish...

Page 8: ...isplay of testing data with dynamic flexuous curve analysis drawing Settable alarm lower limit displayed on the screen and optical alarm Automatic calculation of leaking quantity and leaking rate of t...

Page 9: ...2 5 Pumping Speed 0 4L min 6 Continuous Working Time 5 hours 7 Dashboard Preheat Start up Time 2 minutes 8 Response Time 5 Seconds 9 Recovery Time 10 Seconds 10 Communication Interface USB 1 1 11 Pow...

Page 10: ...s in the parameter import interface to alter time in the clock setting interface to choose items in the historical record interface Return Press Return to return to the testing page of the main menu S...

Page 11: ...election including Enter Test Status Inquire Historic Data and Device Function Setting At the same time the sensor self check and the battery level will also be displayed Enter Test is the default set...

Page 12: ...arge the battery for 4 hours when the battery level is under 25 Figure 3 3 3 After selecting Enter Test Status touch Enter to enter test status after a beep is heard During the sensor preheating the i...

Page 13: ...alarm point in the item Warning Density Setting by choosing the up down left or right keys in Alarm Concentration Setting Choose Left and Right keys to choose different items and Up and Down keys for...

Page 14: ...g will start running See Figure 7 below Figure 7 Item Measured Density shows the real time data of the current test Max Density shows the peak value of the current test Warning Density refers to the a...

Page 15: ...LED key again to turn off the LED light 3 9 During the process if the Measure key on the handle trigger is touched or the measuring process has lasted for 4 minutes the instrument will buzz and the me...

Page 16: ...refer to Figure 11 below Figure 11 After setting touch the Confirm key for data saving process The maximum storage capacity is 100 data When the data saving process is finished the instrument will aut...

Page 17: ...d rate annual leakage annual leakage rate and curve chart etc If Delete is chosen the chosen data will be deleted If Back is chosen the instrument will turn to Function Selection Interface Figure 2 Fi...

Page 18: ...rument panel and return to the upper interface Please refer to Figure 15 below Figure 15 3 16 Enter Display Settings function and touch Up or Down key to set the brightness of the screen After adjustm...

Page 19: ...e 16 below Figure 17 3 18 When you enter Instrument calibration function the instrument can be calibrated on site for the drift after it has been put into use for some time To ensure the reliability o...

Page 20: ...a curve Please refer to Figure 19 below Figure 19 After 10 seconds the calibration will stop and cue works will appear on the interface that the calibration has been completed and the instrument will...

Page 21: ...Through upper computer software the data in the instrument can be received analyzed and saved on the PC end 3 22 Please charge the instrument when the battery power is lower than required battery leve...

Page 22: ...4 3 SF6 gas in standard density of 100ppm is required if the user would like to calibrate the instrument Otherwise the accuracy of the instrument might be affected 4 4 If the measuring process is don...