Section 2—Models 58MVP and 355MAV Direct-Vent, Multipoise, Hot-Surface Ignition, Variable-Speed, Condensing Furnaces. This kit is
designed for use in furnaces with 40,000 through 120,000 Btuh gas input rates.

IMPORTANT:

This kit can replace conversion kit KGANP250112SP, as specified on unit rating plate, when gas valve is replaced with

Two-Stage Gas Valve P/N EF33CW198 (White-Rodgers 36E55). Replacement gas valve available through RCD.

WARNING: Improper installation, adjustment, alteration, service, maintenance, or use can cause carbon monoxide

poisoning, explosion, fire, electrical shock, or other conditions which could result in personal injury or death. Consult a
qualified installer, service agency, local gas supplier, or your distributor or branch for information or assistance. The
qualified installer or agency must use only factory-authorized kits or accessories when modifying this product. Failure to
follow instructions could result in serious injury or property damage.

CAUTION: Gas supply MUST be shut off before disconnecting electrical power and proceeding with conversion.

DESCRIPTION AND USAGE

This kit is designed for use in the furnaces listed above. See Table 1 for kit contents. More parts are shipped in kit than will be needed to complete
conversion. When installation is complete, discard extra parts.

INSTALLATION

SECTION 1—MODELS 58DXT, 58TMA, 58TUA, 58UHV, 58UXT, 58UXV, 330AAV, 330JAV, 331AAV, 331JAV, 333BAV, AND 333JAV
INDUCED-COMBUSTION, HOT-SURFACE IGNITION, 2-SPEED AND VARIABLE-SPEED, NON-CONDENSING FURNACES

PROCEDURE 1—INSTALL MAIN BURNER ORIFICES

NOTE:

See Fig. 1 or 2 for component location.

CAUTION: DO NOT redrill burner orifices. Improper drilling (burrs, out-of-round holes, etc.) can cause excessive

burner noise and misdirection of burner flames. This can result in flame impingement of the burners and heat exchangers,
causing failure. Obtain new orifices if orifice size must be changed.

Table 1 — Kit Contents

DESCRIPTION

PART NO.

QUANTITY

Main Burner Orifice (Drill Size 1.25mm)

LH32DB209

7

Main Burner Orifice (Drill Size No. 55)

LH32DB201

7

Main Burner Orifice (Drill Size No. 56)

LH32DB206

7

Diverter Plate

323184-301

1

Low Gas Pressure Switch (Propane) (LGPS)

HK02LB018

1

Pipe Nipple (1/8 in. X 1-1/2 in.)d

CA01CA006

1

90° Street Elbow (1/8 in.)

CA15RA001

1

Splice Connector (1/4 in. Male, Both Ends)

6617D55

1

Splice Connector (3/16 in. Male, Both Ends)

HY89SC047

1

Orange Wire Assembly (18 in.)

W183X23-04-018

2

Yellow Wire Assembly (6 in.)

W183Y66-11-014

1

Yellow Wire Assembly (14 in.)

W183Y66-11-014

1

Wire Tie

HY76TB125

1

Conversion Rating Plate Label-NonCondensing Furnaces

326108-201

1

Conversion Rating Plate Label-Condensing Furnaces

326108-203

1

Conversion Responsibility Label

326108-204

1

Gas Control Conversion Label

326108-202

1

Installation Instructions

AG-GANP-23

1

A96249

BURNER 
ORIFICE

BURNER 
ORIFICE

—2—

Summary of Contents for KGANP26012SP

Page 1: ...is conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction If...

Page 2: ...ra parts INSTALLATION SECTION 1 MODELS 58DXT 58TMA 58TUA 58UHV 58UXT 58UXV 330AAV 330JAV 331AAV 331JAV 333BAV AND 333JAV INDUCED COMBUSTION HOT SURFACE IGNITION 2 SPEED AND VARIABLE SPEED NON CONDENSI...

Page 3: ...anne a Be sure gas and electrical supplies to furnace are off b Remove wires from gas valve Note location for reassembly c Remove wires from flame sensor and flame rollout safety switch es Disconnect...

Page 4: ...pply 13 Remove manometer but do not reinstall gas valve inlet pressure tap plug See Fig 3 PROCEDURE 4 INSTALL LOW GAS PRESSURE SWITCH LGPS NOTE The inlet gas pipe must be disconnected from valve so pr...

Page 5: ...nal tightening When pressure switch is tight switch terminals should point as shown in Fig 8 relative to gas valve and clear control compartment access door 5 Apply pipe dope sparingly to end of inlet...

Page 6: ...main gas and electric supplies to furnace are off 2 Remove 1 8 in pipe plug from manifold pressure tap on downstream side of gas valve See Fig 3 3 Attach manometer to manifold pressure tap on gas val...

Page 7: ...r propane is the same as for natural gas See furnace rating plate for input rate The input rate for propane is determined by manifold pressure and orifice size The gas valve regulator must be set for...

Page 8: ...old pressure tap plug See Fig 3 NOTE Use propane gas resistant pipe dope to prevent gas leaks DO NOT use Teflon tape 7 Turn on furnace power supply 8 Turn furnace gas valve switch to ON position 9 Set...

Page 9: ...de c blage peut tre une source de danger et de panne 7 Remove burner box pressure tube from gas valve burner enclosure reference pressure tap fitting See Fig 11 8 Remove screws that secure manifold to...

Page 10: ...CONTROL CONVERSION LABEL Fig 11 Redundant Automatic 2 Stage Gas Valve A99218 ON O F F ON OFF SWITCH INLET PRESSURE TAP BURNER ENCLOSURE REFERENCE PRESSURE TAP VARIABLE SPEED CONDENSING FURNACES ONLY M...

Page 11: ...egulator fitting 5 Reconnect gas supply pipe to gas valve using backup wrench on gas valve to prevent rotation and improper orientation NOTE Use propane gas resistant pipe dope to prevent gas leaks DO...

Page 12: ...tall gas valve inlet pressure tap plug See Fig 11 NOTE Use propane gas resistant pipe dope to prevent gas leaks DO NOT use Teflon tape PROCEDURE 6 INSTALL LOW GAS PRESSURE SWITCH LGPS A 6 INSTALL LOW...

Page 13: ...nducer housing Add 1 4 in splice connector to this wire 2 Connect uninsulated terminal of 1 orange wire provided in kit to splice connector Connect other end to C terminal on low gas pressure switch L...

Page 14: ...11 32 7 8 C L C L IGNITOR ASSEMBLY IGNITOR ASSEMBLY CELL PANEL BURNER BURNER BOX Fig 17 Adjusting Manifold Pressure Manifold Attachment A94351 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 BURNER ENCLOSURE REMOVE COV...

Page 15: ...ODE RECALL LOW HEAT ONLY BPH BYPASS HUMIDIFIER EMERGENCY HEAT MZ MULTI ZONE COMPONENT TEST HEATING BLOWER OFF TIME DELAY Fig 19 Installation of Low Gas Pressure Switch A99222 OFF STREET ELBOW 1 8 IN N...

Page 16: ...hermostat connections See Fig 18 This keeps furnace locked in high heat operation e Adjust high heat input rate manifold pressure for propane gas See kit rating plate 326108 203 f Turn high heat adjus...

Page 17: ...rners until after hot surface ignitor begins glowing PROCEDURE 11 LABEL APPLICATION NOTE See Fig 10 for label location 1 Fill in Conversion Responsibility Label 326108 204 and apply to blower access p...

Page 18: ...18...

Page 19: ...19...

Page 20: ...2000 CAC BDP P O Box 70 Indianapolis IN 46206 agganp23 20 Book Tab 1 6a 4 8a Catalog No 63GA NP5...

Reviews: