HFR-8000 Operator

’s Manual for Remote Tracing

 

11

 

2.4 Safety Precautions 

This  equipment  has  been  developed  and  tested  according  to  safety  standards  as 

well  as  national  and  international  standards.  This  guarantees  a  very  high  degree  of 

safety  for  this  device.  The  legislator  expects  us  inform  the  user  expressively  about 

the safety aspects in dealing with the device. The correct handling of this equipment 

is  imperative  for  its  safe  operation.  Therefore,  please  read  carefully  all  instructions 

before  switching  on  this  device.  For  more  detailed  information,  please  contact  our 

Customer Service Department or one of our authorized representatives. 

 

  This  equipment  must  not  be  used  (a)  in  an  area  that  is  in  danger  of  explosions 

and  (b)  in  the  presence  of  flammable,  explosive,  or  volatile  solvent  such  as 

alcohol, benzene or similar chemicals. 

 

② 

Do  not  put  or  use  this  device  in  humid  rooms.  Humidity  should  be  maintained 

between 50% and 80% for normal operation.    Do not expose the device to water 

splashes,  dripping  water,  or  sprayed  water.  Do  not  place  containers  containing 

fluids, liquids, or gases on top of any electrical equipment or devices. 

 

③ 

The  equipment  must  be  operated  only  by,  or  under  direct  supervision  of  a 

properly trained and qualified person. 

 

④ 

The service technician of Huvitz or the technician authorized by Huvitz may only 

carry out modifications of this equipment. 

 

⑤ 

Customer maintenance of this equipment may only be performed as stated in the 

Use

r’s  Manual  and  Service  Manual.  Any  additional  maintenance  may  only  be 

performed  by  the  service  technician  of  Huvitz  or  the  technician  authorized  by 

Huvitz. 

 

⑥ 

The  manufacturer  is  only  responsible  for  effects  on  safety,  reliability,  and 

performance  of  this  equipment  when  the  following  requirements  are  fulfilled:  (1) 

The electrical installation in the respective room corresponds to the specifications 

Summary of Contents for HFR-8000

Page 1: ...Operator s Manual HFR 8000 For Remote Tracing...

Page 2: ...ate at the time of publication HUVITZ assumes no responsibility however for possible errors or omissions or for any consequences resulting from the use of the information contained herein HUVITZ reser...

Page 3: ...5 2 Safety Information 6 2 1 Introduction 6 2 2 Safety Symbols 7 2 3 Environment factors 8 2 4 Safety Precautions 11 3 System Configuration 15 3 1 Frame Reader 15 3 2 Standard Accessory 16 4 Installa...

Page 4: ...7 1 Interface Specification 24 7 2 Connecting to a DCS host 25 7 3 DCS Options 26 7 4 Using the Barcode Interface for Inputting Job Number 27 8 System Maintenance 29 8 1 Automatic Calibration of Fram...

Page 5: ...th e stylus position into the frame groove especially when the groove is lopsided SEMI AUTO demo lens tracing mode is additionally provided for recognizing and processing concave shape Barcode scanne...

Page 6: ...r s Manual for Remote Tracing 5 in an environment with continuous operation over a long period of time 1 3 Classification Protection against electric shock Class I earthed Installation Category II Pol...

Page 7: ...the user operator It is for this reason that the following safety notices have been placed appropriately within the text of this manual to highlight safety related information or information requirin...

Page 8: ...afety ground is fastened to the chassis Protective earth connected to conductive parts of Class I equipment for safety purposes Disposal of your old appliance 1 When this crossed out wheeled bin symbo...

Page 9: ...use only Where the machine is exposed to direct sunlight Where there are big changes in temperature Optimal temperature range for normal operation is from 10 C to 40 C Humidity 30 80 Where there is a...

Page 10: ...ill cause severe damage on the machine Pull out the power cord with holding the plug not the cord To avoid risk of electric shock this equipment must only be connected to a supply mains with protectiv...

Page 11: ...ge of 10 95 with non condensing An atmospheric pressure range of 700 1060hpa 4 Temporary Overvoltage Short term temporary overvoltage 1440V Long term temporary overvoltage 490V Please avoid where the...

Page 12: ...ar chemicals Do not put or use this device in humid rooms Humidity should be maintained between 50 and 80 for normal operation Do not expose the device to water splashes dripping water or sprayed wate...

Page 13: ...authorized to install use operate and maintain this equipment Keep accompanied manual s or technical materials such as the User s Manual and Service Manual in a place easily accessible at all times fo...

Page 14: ...mble the product without the proper training It may cause the electric shock serious hurt during the operation or cause the malfunction of the product The product should be properly installed and main...

Page 15: ...sure the locking device and the screw for the cover are properly tightened In case of packaging the equipment use the recommended packaging material and method in order to prevent the damage during th...

Page 16: ...System Configuration 3 1 Frame Reader Front View Rear View Protection Door Control Panel Work Space for Stylus Display Window Gripper Gripping Bar Stylus Main Switch Power Inlet Fuse Holder Interface...

Page 17: ...16 HFR 8000 Operator s Manual for Remote Tracing 3 2 Standard Accessory Pattern Holder Standard Pattern Standard Frame...

Page 18: ...e the shock absorbing material from the workspace of Stylus Plug the Power Cable into the power inlet at the back of the product and turn on the power to check the initial operation If the initial ope...

Page 19: ...cing Mode LO CURV 2D Tracing HI CURV 3D Tracing When the Pattern Holder is loaded in the Frame Reader it automatically recognizes the pattern tracing mode When tracing a demo lens of higher curve usin...

Page 20: ...n one of the tracing buttons for 2 seconds will executes the SEMI AUTO tracing mode which is to allow recognizing concave shape while tracing Otherwise it doesn t recognize concave shape and reform it...

Page 21: ...gripping bar Select the frame material by the material selection button Press one of the tracing buttons BOTH for both sides R for right or L for left Pattern Tracing Put a pattern or a blocked demo l...

Page 22: ...reverses the selection FRAME button selecting a configuration parameter in a menu category Holding down the button for 2 seconds reverse the selection BOTH button executing a selected parameter for c...

Page 23: ...the port EDGER PC NONE PROTO 1 Data communication protocol for EDGER 1 port HUVITZ DCS DCS_Z BPS 1 Baud rate for EDGER 1 port 9600 14400 19200 57600 115200 38400 EDGER 2 Target device for EDGER 2 port...

Page 24: ...g mode YES NO MINI FR Low speed tracing option for frames with minimal vertical size YES NO FPD OFF FPD offset 2 99 2 99 JOB NO Job number reset option Turning on the option keep the last job number e...

Page 25: ...specification of the communication port of the Frame Reader for interfacing PC follows the information below Baud Rate 115200 57600 38400 19200 14400 or 9600 Data Bit 8 Stop Bit 1 Parity None Flow con...

Page 26: ...ing a lab management software or a host program on it make it sure to turn the instrument off Procedure Connect PC to EDGER1 port with a 9 pin DSUB crossed serial cable Connect a barcode reader to the...

Page 27: ...1 for menu operation Set at least one of EDGER 1 and EDGER 2 port like bellows EDGER 1 2 PC PROTO 1 2 DCS or DCS_Z Change the menu category to DCS DCS menu category is activated only if one of the edg...

Page 28: ...ngle side is traced YES NO FRAME Default frame material for a job for DCS output METAL Metal PL HARD Hard Plastic PL SOFT Soft Plastic UNDEFIN Undefined OFF Do not output frame material info METAL PL...

Page 29: ...ps and prompts to scan a barcode Scan a barcode and it ll display the number for a second on the screen Frame tracing is automatically started after the job number input The job number is transmitted...

Page 30: ...for frame reader consists of three parts Stroke Frame Pattern In case of any change happened in the stylus do the full calibration in the following sequence Stroke calibration Frame calibration Patte...

Page 31: ...n menu Calibration results are stored in its permanent memory automatically right after the completion of each calibration Be sure to check the related information before executing the calibration wor...

Page 32: ...B PATTERN menu Refer to the section 6 1 for menu operation Press the BOTH button two times to trigger the automatic calibration It traces the standard pattern twice If it result in any error check if...

Page 33: ...ess MENU button and select the CALIB STROKE menu Refer to the section 6 1 for menu operation Press the BOTH button two times to trigger the automatic calibration If it result in any error check the mo...

Page 34: ...t the power cord Since the exterior of the product is easily scratched be sure to use soft cleaning cloth When cleaning the product avoid spraying cleansing agent directly onto the product This may re...

Page 35: ...n for Frame Reader Calibration 1 Pattern Holder 1 Fuse 3 15A 2 Power Cable Frame Reader 1 Option Barcode Scanner 1 9 pin D Sub Serial Cable Crossed 1 Lens Adapter 3 Specification Frame Reader Dimensio...

Page 36: ...HFR 8000 Operator s Manual for Remote Tracing 35 System Dimension...

Reviews: