![Huviron SK-AR12 User Manual Download Page 25](http://html1.mh-extra.com/html/huviron/sk-ar12/sk-ar12_user-manual_2190196025.webp)
Press 'F2' button to input the preset speed.
Press 'F3' button to set dwell time.
Press 'F7' button to input a group number.
Use the joystick and zoom control button to move the camera to the desired
location.
Press 'F4' button to save the setting values.
F2
F7
PRESET
CAM:001
NUM :000
Group:1
MOVE
SPD:020
DWL:005
SAVE
[
[
[
[
[
]
[
]
[
]
]
]
]
]
Notice : Some functions would be not selectable according to protocol.
Preset setup is also available in the OSD menu of the connected PTZ
camera.
F4
F3
Some commands of PELCO-D have special functions other than preset.
1. 33+preset FLIP COMMAND
2. 97+preset RANDOM SCAN
3. 98+preset FRAME SCAN
4. 99+preset AUTO SCAN
- Some would be not available according to protocol.
- Each camera might have some differences between the specification and
real operation.
25
Chapter 4. How to use