![Huviron SK-AR12 User Manual Download Page 14](http://html1.mh-extra.com/html/huviron/sk-ar12/sk-ar12_user-manual_2190196014.webp)
②Connection for Full Duplex
- Connect TX(+) terminal on the junction box of the master controller to TX(+) terminal on
the junction box of the slave controller.
- Connect TX(-) terminal on the junction box of the master controller to TX(-) terminal on
the junction box of the slave controller.
- Connect RX(+) terminal on the junction box of the master controller to RX(+) terminal
on the junction box of the slave controller.
- Connect RX(-) terminal on the junction box of the master controller to RX(-) terminal
on the junction box of the slave controller.
3.3 General Connection
1) One keyboard to one device
2) One keyboard to multiple device
14
Chapter 3. System Connections
Summary of Contents for SK-AR12
Page 1: ...SYSTEM CONTROLLER USER MANUAL...
Page 10: ...2 3 Product Components 10 Controller Cable Junction Box Manual Chapter 2 How to install...
Page 15: ...3 Multiple keyboards to multiple devices Master Slave Chapter 3 System Connections 15...
Page 33: ...ST ART PATTERN SETUP STOP RUN END 33 Chapter 4 How to use...