6
NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 50 cm from the floor.
•
Open the cover of the heater’s electrical box.
•
Attach the power cable on the terminal block according to the
circuit diagram.
• Close the cover.
•
Fix the cable on the output with a cable strap.
Fittingthestones
Upon stacking the stones, one should monitor that the heating
elements are not bent and that there is a sufficient air circulation
around the heater elements.
• The stones must be washed clean before laying.
• When the stones have been stacked too close to each other, the
heating elements may overheat (= shorter useful life) and slow the
heating of the sauna.
•
Stones with a diameter of 3–5 cm are suitable for the heater.
•
The stones on the external surface of the heater must fully cover
the heating elements. The heating elements must not be visible.
• Using ceramic stones in the STEEL heater is allowed upon the
user’s responsibility.
ATTENTION!
Too sparsely filled stone container causes fire hazard!