background image

Rev. 9610(9911)

9

Maintenance

ELECTRICAL PRECAUTIONS

BEFORE SERVICING – Always disconnect

electrical power at the main disconnect when

servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with a shatterproof pro-
tective coating. The same type of lamp with protective
coating must be used if replaced.

This lamp has been treated to resist breakage and must be
replaced with a similarly treated lamp in order to maintain
compliance with NSF Standards. 
              NSF CODE 4.28.1

Contact HUSSMANN Chino for replacement

1-800-395-9229 x 2131

T-5 BULBS

Please note: T-5 lights must be turned off and on 

after

 bulb

replacement.

EVAPORATOR FANS

The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.

Should fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.

COPPER COILS

The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1. Check electrical power supply to the equipment for

connection.

2. Check fixture loading. Overstocking case will affect

its proper operation.

3. If frost is collecting on fixture and/or product, check

that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter store.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial

Number handy. This information is on a plate

located on the case itself.

Summary of Contents for RID

Page 1: ... Chino RID ROLL IN DELI DAIRY DISPLAY REV 9610 9911 Installation Operation Manual RID ROLL IN DELI DAIRY DISPLAY P N IGUP RID 9610 9911 INSTALLATION OPERATION GUIDE ...

Page 2: ...TAGES Check your shipment for any possible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier imme diately and request an inspection Hussmann Chino will acknowledge shortages within ten days from receipt of equipment HUSSMANN CHINO PRODUCT CONTROL The serial numb...

Page 3: ...VIEW Single Sided 3 6 18 18 Ref Drain 4 Elec SINGLE OR DOUBLE DEPTH VARIABLE LENGTHS ELEC FLEXED ASSEMBLED IN FIELD DRAIN IS 1 PLASTIC TUBE REFRIG STUBBED UP THROUGH TOP FRONT 4 Elec 8 10 1 2 SINGLE DEPTH VARIABLE LENGTHS ELEC FLEXED ASSEMBLED IN FIELD DRAIN IS 1 PLASTIC TUBE REFRIG STUBBED UP THROUGH TOP FRONT 6 18 14 1 4 Ref Drain 4 Elec FRONT 13 0 5 8 DOUBLE DEPTH PLAN VIEW C L 6 18 14 1 4 Drai...

Page 4: ...se The RID case is tall and narrow and can be tipped over if it is raised too high on one side JOINING NOTE FOR EASE OF INSTALLATION IT IS RECOMMENDEDTHATTHE UNIT IS ASSEMBLED BY A CREW OF THREE TO FOUR 3 4 PEOPLE AND ONE 1 FORKLIFT During the development of this product a simulated field installation was carried out to identify the simplest method of assembly To reduce installation time and to av...

Page 5: ...prevent draining 3 Always provide as much down hill slope fall as possible 1 8 per foot is the preferred minimum PVC pipe when used must be supported to maintain the 1 8 pitch and to prevent warping 4 Avoid long runs of condensate drains Long runs make it impossible to provide the fall necessary for good drainage 5 Provide a suitable air break between the flood rim of the floor drain and outlet of...

Page 6: ...er each access panel at end of the case ELECTRONIC The Electronic Expansion valve master and slave cylinder s are located within the electrical access panel s ELECTRONIC EXPANSION VALVE OPTIONAL A wide variety of electronic expansion valves and case controllers can be utilized Please refer to EEV and con troller manufacturers information sheet Sensors for elec tronic expansion valves will be insta...

Page 7: ... lighting for all models will be full length fluores cent lamps located within the case at the top The switch controlling the lights the plug provided for digital scale and the thermometer are located at the rear of the case mullion FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may be less than specified Field wir...

Page 8: ... O will shorten the shelf life of the product 8 Do not set temperature too cold as this causes product dehydration Process the meat to enter case at 40 or below Product deterioration is very rapid above 40 CASE CLEANING Long life and satisfactory performance of any equipment are dependent upon the care given to it To insure long life proper sanitation and minimum maintenance costs the refrigerator...

Page 9: ...ans are located at the center front of these merchandisers directly beneath the display pans Should fans or blades need servicing always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR COPPER COILS The copper coils used in Hussmann merchandisers may be repaired in the field Materials are available from local refrigeration wholesalers Hussmann recommends using 15 Sil ...

Page 10: ...700 12 36 28 450 Optional 2 60 8 x 30 50 min 1 98 3 6 2 6 Tube 6 3 8 2700 12 36 28 450 Optional 2 60 8 x 30 50 min 2 64 4 8 2 6 Tube 8 3 12 2700 12 36 28 450 Optional 2 60 8 x 30 50 min 3 96 7 2 5 4 Tube 12 3 RID 03 Single Sided Double Depth 4 2700 12 36 28 450 Optional 60 8 x 30 50 min 6 1 2 98 Tube 2 3 6 2700 12 36 28 450 Optional 60 8 x 30 50 min 9 1 8 1 3 Tube 3 3 8 2700 12 36 28 450 Optional ...

Page 11: ...luation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to manufacturer s recommendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c At the same time check...

Page 12: ...ing or diverting air flow 10 Are the coils of the refrigerator iced up 11 Is the store ambient over 75 F 55 RH as set forth in ASHRAE Standard 72 and ASHRAE Standard 117 12 Are the shelf positions number and size other than recommended by the manufac turer 13 Is there an improper application or control system 14 Is the evaporator fan motor blade inopera tive 15 Is the defrost time excessive 16 Ist...

Page 13: ...ity f Minimize the transfer time of perishables from storage to display g Keepmeatunderrefrigerationinmeatcuttingand processing area except for the few moments it is being handled in processing When a cut or tray of meat is not to be worked on immediately the procedure should call for returning it to refrigera tion h Keep tools clean and sanitized Since mechanical equipment is used for fresh meat ...

Page 14: ...IGUP RID 9610 9911 14 ...

Page 15: ...n under this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor assembly is available but must be purchased prior to shipment to be in effect Hussmann reserves the right to inspect the job site installation and reason for failure The motor compressor warrantie...

Page 16: ...particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by contacting Hussmann Chino 13770 RamonaAvenue Chino California 91710 909 628 8942 FAX 909 590 4910 800 395 9229 Service Record Last service date By ...