Rev. 9610(9911)
7
Electrical
WIRING COLOR CODE
C o l o r D e s c r i p t i o n
D e s c r i p c i o n
D e s c r i p c i o n
G RO U N D
T I E R R A M A S A
M A S S E
A N T I - S W E AT
A N T I C O N D E N S C I O N
A N T I - S U I N T E M E N T
L I G H T S
L U C E S
E C L A I R A G E
R E C E P TA C L E S
E N C H U F E R
R E C E P TA C L E
T- S TAT / S O L E N O I D 230 V THERMOSTATO / SOLENOID (230 VAC)
SOUPAPE A SOLENOID (230 V)
T- S TAT / S O L E N O I D 115 V THERMOSTATO / SOLENOID (115 VAC)
SOUPAPE A SOLENOID (115 V)
FAN MOTORS
VENTILADORES
VENTILATEUR
S TA N DA R D C A S E W I R E C O L O R C O D E
C O D I G O D E C O L O R E S D E L O S A L A M B R E S PA R A L A S V I T R I N A S E S TA N DA R
C O D E C O U L E U R P O U R F I L S D E B O I T I E R N O R M A L I S E
4 3 0 - 0 1 - 0 3 3 8 r 9 9 0 8
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the “TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length fluores-
cent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for re-
frigeration thermostats. Most component amperes are
listed in the “Case Specs” section, but always check the
serial plate.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heat-
ers, Thermostats, and Lights.
BALLAST LOCATION
Ballasts are located within the access panel that runs
the length of the rear of the case. Refer to diagram on
page 6.