REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

RI3N

Discharge Air (°F)

27

Evaporator (°F)

20

Unit Sizing (°F)

18

Btu/hr/ft

L

IT

& U

NLIT

S

HELVES

RI3N

Parallel

1820

Conventional

1985

DEFROST DATA

RI3N

Frequency (hr)

4

Defrost Water (lb/ft/day)

12

(± 15% 

based on case configuration and 

product loading).

O

FF

T

IME

RI3N

Time Terminated (minutes)

20

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

RI3N

14°F / 4°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to 

determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

5

/

8

Estimated Charge (lb)**

8 ft 

1.7

10 ft 

2.1

12 ft 

2.5

14 ft

3.1

16 ft

3.7

**This is an average for all refrigerant types.

Actual refrigerant charge may vary 

by approximately half a pound.

3 of 6

P/N 0503950_A

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

18

 1/8

 

(460)

51

 3/4

 

(1315)

9

 7/8

 

(251)

6

 (152)

14

 1/8

 

(359)

5

 1/2

 

(140)

49

 

(1245)

60

 

(1524)

5

 1/2

 

(140)

10

 7/8

 

(276)

1/4

 

(83)

5

 

7/8

 

(149)

(76)

27 

(686)

8

 

(203)

12 

(305)

16 

(406)

Dimensions shown as in. and (mm).

Multi-deck Island, 4 Display Level, Narrow Footprint

RI3N

RI3N

Multi-deck Island

Load Limit

Load Limit

RI3N

Optional High Plex 
with 6 in. (152 mm) 
Product Depth

Optional Shelves

Load Limit Profile

Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should 
merchandisers be stocked beyond the load limits indicated.

Cases may not function properly if they are loaded above load limits.

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for con-
struction, materials & cleanability.

Summary of Contents for RI3-N

Page 1: ...escription Wiring Item HEATERS C Anti Sweat Heater 3 0487118 8 10 ft HE 4850668 0487119 12 ft HE 4850834 0487120 14 ft HE 4850835 0487121 16 ft HE 4850836 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 0459491 BA 4481566 E Fluorescent Lamp 5 Replace with like fixtures 2008 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 19...

Page 2: ... 8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93...

Page 3: ...efrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 6 P N 0503950_A HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 18 1 8 460 51 3 4 1315 9 7 8 251 6 152 14 1 8 359 5 1 2 140 49 1245 60 1524 5 1 2 140 10 7 8 276 3 1 4 83 5 7 8 149 3 76 27 686 8 203 12 305 16 406 Dimensions shown as in and mm Multi deck Island 4 Display Level Narrow Footprint ...

Page 4: ... Standard 5 31 6 81 8 48 11 66 13 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 61 3 21 3 98 5 36 6 13 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting 1 Row Canopy 0 53 0 53 0 83 1 07 1 37 64 64 100 128 164 Optional Lighting 1 Row of ...

Page 5: ... S A WWW HUSSMANN COM Fan Wiring Offtime Defrost ESTIMATED SHIPPING WEIGHT 5 Case Solid End 8 ft 10 ft 12 ft 14 ft 16 ft each lb kg 1100 499 1300 590 1600 726 1800 816 2100 953 NA NA 5 Actual weights will vary according to optional kits included R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandise...

Page 6: ... W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf configurations and different case lengths will have more shelf ballasts Lighted Shelf Wiring Preliminary R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the...

Reviews: