REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
RI3N
Discharge Air (°F)
27
Evaporator (°F)
20
Unit Sizing (°F)
18
Btu/hr/ft
L
IT
& U
NLIT
S
HELVES
RI3N
Parallel
1820
Conventional
1985
DEFROST DATA
RI3N
Frequency (hr)
4
Defrost Water (lb/ft/day)
12
(± 15%
based on case configuration and
product loading).
O
FF
T
IME
RI3N
Time Terminated (minutes)
20
E
LECTRIC OR
G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
*
RI3N
14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination*
48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
5
/
8
Estimated Charge (lb)**
8 ft
1.7
10 ft
2.1
12 ft
2.5
14 ft
3.1
16 ft
3.7
**This is an average for all refrigerant types.
Actual refrigerant charge may vary
by approximately half a pound.
3 of 6
P/N 0503950_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
18
1/8
(460)
51
3/4
(1315)
9
7/8
(251)
6
(152)
14
1/8
(359)
5
1/2
(140)
49
(1245)
60
(1524)
5
1/2
(140)
10
7/8
(276)
3
1/4
(83)
5
7/8
(149)
3
(76)
27
(686)
8
(203)
12
(305)
16
(406)
Dimensions shown as in. and (mm).
Multi-deck Island, 4 Display Level, Narrow Footprint
RI3N
RI3N
Multi-deck Island
Load Limit
Load Limit
RI3N
Optional High Plex
with 6 in. (152 mm)
Product Depth
Optional Shelves
Load Limit Profile
Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should
merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for con-
struction, materials & cleanability.