background image

2 of 6

RI3N

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

RI3N Island

A

B

Electrical Service

Drains

Refrigeration 

& Coil Stubout

27 

(686)

(178)

49 

(1245)

32

 

1

/2

 

(826)

11

 

1

/2

 

(292)

9

 

1

/2

 

(241)

22 

(559)

72 

(1829)

31

 

1

/4

 

(794)

20

 

3

/8

 

(518)

Engineering

Plan Views

06-2003

Front

8 ft

10 ft

12 ft

14 ft

16 ft

General

(A)

Base Length

77 (1956)

101 

7

/

(2588)

125 

7

/

(3198)

149 

1

/

(3798)

173 (4396)

Overall Case Length

96 (2438)

120 (3048)

144 (3658)

168 (4267)

192 (4876)

Maximum O/S dimension of case back to front 

(includes bumper)

60 (1524)

60 (1524)

60 (1524)

60 (1524)

60 (1524)

Front of splashguard to O/S edge of front base rail

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

Front of case to O/S edge of front base rail

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

Back of case to O/S edge of front base rail

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

Width of base rail

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

Electrical Service                             

(Electrical Field Wiring connection point)

Center of Electrical service to O/S edge of front base rail

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

Right end of case to center of knockout

27 (686)

27 (686)

27 (686)

27 (686)

27 (686)

Left end of case to center of knockout

69 (1753)

93 (2362)

117 (2972)

141 (3581)

165 (4191)

Waste Outlets

(B)

LH End of case to the center of waste outlet

48 (1219)

78 (1981)

102 (2591)

84 (2134)

96 (2439)

Center of front waste outlet to outside of front base rail

8 (203)

8 (203)

8 (203)

8 (203)

8 (203)

Center of back waste outlet to outside of front base rail

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

LH end of case to center of refrigeration outlet

22 (559)

22 (559)

22 (559)

22 (559)

22 (559)

RH end of case to center of refrigeration outlet

74 (1880)

98 (2489)

122 (3098)

146 (3708)

170 (4318)

Serial Plate
End

Summary of Contents for RI3-N

Page 1: ...escription Wiring Item HEATERS C Anti Sweat Heater 3 0487118 8 10 ft HE 4850668 0487119 12 ft HE 4850834 0487120 14 ft HE 4850835 0487121 16 ft HE 4850836 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 0459491 BA 4481566 E Fluorescent Lamp 5 Replace with like fixtures 2008 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 19...

Page 2: ... 8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93...

Page 3: ...efrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 6 P N 0503950_A HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 18 1 8 460 51 3 4 1315 9 7 8 251 6 152 14 1 8 359 5 1 2 140 49 1245 60 1524 5 1 2 140 10 7 8 276 3 1 4 83 5 7 8 149 3 76 27 686 8 203 12 305 16 406 Dimensions shown as in and mm Multi deck Island 4 Display Level Narrow Footprint ...

Page 4: ... Standard 5 31 6 81 8 48 11 66 13 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 61 3 21 3 98 5 36 6 13 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting 1 Row Canopy 0 53 0 53 0 83 1 07 1 37 64 64 100 128 164 Optional Lighting 1 Row of ...

Page 5: ... S A WWW HUSSMANN COM Fan Wiring Offtime Defrost ESTIMATED SHIPPING WEIGHT 5 Case Solid End 8 ft 10 ft 12 ft 14 ft 16 ft each lb kg 1100 499 1300 590 1600 726 1800 816 2100 953 NA NA 5 Actual weights will vary according to optional kits included R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandise...

Page 6: ... W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf configurations and different case lengths will have more shelf ballasts Lighted Shelf Wiring Preliminary R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the...

Reviews: