FRONT BODY PANEL REMOVED
FOR ACCESS TO FRONT CASE BOLTING
FRONT CASE BOLT
(UPPER 3/8" HOLE)
LINE-UP PLATE
(INSERT INTO VERTICAL SLOT)
LINE-UP PIN
(INSERT INTO OUTER 1/2" HOLE)
CASE BOLTING (MULTIPLE 3/8" HOLES)
ACCESS BEHIND AIR DISCHARGE WALL
LINE-UP PLATE
(INSERT INTO ALUMINUM PROFILE)
CASE BOLTING
USE 1/4"- 20 X 1 1/2" SCREW AT TOP
Q SERIES CASE JOINING GUIDE
LINE-UP TAB
(AT BACK OF BUMPER)
Location
3
The refrigerated merchandisers have been designed
for use only in air conditioned stores where temperature
and humidity are maintained at or below 75°F and 55%
relative humidity. DO NOT allow air conditioning, electric
fans, ovens, open doors or windows (etc.) to create air
currents around the merchandiser, as this will impair its
correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.
Installation
Uncrating the Stand
Place the
fi
xture as close to its permanent position as
possible. Keep in place, attached case until ready to set/bolt
to adjoining case.
Tighten Glass Screws
Tighten screws along clamshell located on the underside
of glass before placing unit into operation.
Exterior Loading
These models have
not
been structurally designed to
support excessive external loading.
Do not walk on their
tops;
This could cause serious personal injury and damage
to the
fi
xture.
Q-Series Joining Guide
Summary of Contents for Q1-SSN
Page 11: ...Spec Sheet 11...
Page 19: ...Wiring Diagrams 19...
Page 20: ...Wiring Diagrams Cont d 20...
Page 21: ...Wiring Diagrams Cont d 21...
Page 22: ...Wiring Diagrams Cont d 22...
Page 23: ...Wiring Diagrams Cont d 23...
Page 24: ...Wiring Diagrams Cont d 24...
Page 25: ...Wiring Diagrams Cont d 25...
Page 26: ...Wiring Diagrams Cont d 26...
Page 27: ...Wiring Diagrams Cont d 27...
Page 28: ...Wiring Diagrams Cont d 28...