background image

6 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P4X-E

Technical Data Sheet

Defrost 

Termination 

Thermostat

Refrigeration 

Thermostat

Dark Blue

3

To 
Condensing 
Unit

}

Light Blue

2

2, 4 & 6 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 
 

4 ft 
6 ft 
8 ft 

12 ft

12 ft

5

5

4

4

4

5

5

5

5

5

5

5

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

5

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

5

4

5

5

Connector

W

B

BL

BL

R

BL

R

R

R

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for P4X-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Page 2: ...al legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Page 3: ...Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lbs P4X E 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types ac...

Page 4: ...48 120V 60Hz Energy Efficient 0 80 0 96 1 40 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Stand...

Page 5: ...isplay Area 3 Sq Ft Ft 4 40 ft2 ft 1 34 m2 m Shelf Area 4 Sq Ft Ft 6 88 ft2 ft 2 10 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerate...

Page 6: ...l Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and...

Page 9: ...L R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: