DISPLAY PANS
The NIM-6 is provided with 3 display pans which you should make sure are placed correctly and never operate
the cabinet without these. If you use the case without these display pans the interior airflow and temperature in
the cabinet will be adversely affected
AIR DISTRIBUTION
The NIM-6 and NIM-4 cabinets are sensitive to air disturbances. Air currents passing around cabinets will
seriously impair their operation. DO NOT allow air conditioning, electric fans, open doors or windows, etc. to
create air currents around the cabinets.
LOAD LIMITS
Each merchandiser has a load limit decal. Shelf life of perishables will be short if load limit is violated.
Overstocking will adversely affect product temperature and cabinet efficiency
.
ELECTRIC CONNECTIONS
It is very important for your safety and that of your customers that this cabinet be grounded. A qualified
electrician must make the electrical installation, in accordance with the national or local electric codes.
NOTE: Connecting this cabinet to any electric supply other than specified on the serial plate, will void the
warranty and it can cause severe damage to the unit.
WARNING
Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical
component. This includes, but is not limited to, such items as fans, heaters, thermostats and lights.
HONEY
COMB
DISCHARGE
PAN
DISPLAY
TEMPERATURE
CONTROL
DOORS GLASS
TEMPERED