background image

 

DISPLAY  PANS 

   
The NIM-6 is provided with 3 display pans which you should make sure are placed correctly and never operate 
the cabinet without these. If you use the case without these display pans the interior airflow and temperature in 
the cabinet will be adversely affected 
   

AIR DISTRIBUTION  

The NIM-6 and NIM-4 cabinets are sensitive to air disturbances.  Air currents passing around cabinets will 
seriously impair their operation.  DO NOT allow air conditioning, electric fans, open doors or windows, etc. to 
create air currents around the cabinets.  
  

LOAD LIMITS 

Each merchandiser has a load limit decal.  Shelf life of perishables will be short if load limit is violated.  

Overstocking will adversely affect product temperature and cabinet efficiency

.   

   

ELECTRIC CONNECTIONS   

 
It is very important for your safety and that of your customers that this cabinet be grounded.  A qualified 
electrician must make the electrical installation, in accordance with the national or local electric codes.   
   
NOTE: Connecting this cabinet to any electric supply other than specified on the serial plate, will void the 
warranty and it can cause severe damage to the unit.   
   

WARNING 

Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical 
component.  This includes, but is not limited to, such items as fans, heaters, thermostats and lights.   
   
   
   
 
 
  

           

 

                 
    
 
 
 
 
 

   

HONEY 
COMB 
DISCHARGE 

PAN 
DISPLAY

TEMPERATURE
CONTROL

DOORS GLASS 
TEMPERED

Summary of Contents for NIM

Page 1: ...E READ THIS MANUAL BEFORE USING THE PRODUCT Installation Operation Manual P N 2402195 NIM 6 January 2003 Hussmann Monterrey Mexico Carretera Mexico Laredo KM 1009 Cienga de Flores Nuevo Leon 65550 Mex...

Page 2: ...Doors 1 Leveling of the Cabinet 2 Sealing Splashguard to Floor 2 Grills 2 Drain 3 Tempered Glass Doors 3 Display Pan 3 Air Distribution 3 Electric connections 4 Serial plate 4 Control of temperature 4...

Page 3: ...abinets is uncrated retain all packing materials and submit a written request to the carrier for inspection within 5 days LOCATION Avoid locating where the light of the sun is direct where air conditi...

Page 4: ...uch the floor is out of level To install the trim to the splashguard 1 Remove all dirt wax and grease from the area of the splashguard where adhesion will be necessary This is to ensure a good and sec...

Page 5: ...nit area The system is designed to evaporate the condensate water It is important to keep this pan clean and free of debris so that it dissipates the water efficiently in order to prevent overflows DO...

Page 6: ...f perishables will be short if load limit is violated Overstocking will adversely affect product temperature and cabinet efficiency ELECTRIC CONNECTIONS It is very important for your safety and that o...

Page 7: ...nt and warm water to protect and maintain their attractive finish NEVER USE ABRASIVE CLEANSERS OR SCOURING PADS Interior Surfaces The interior surfaces may be cleaned with most domestic detergents amm...

Page 8: ...void spills of water after defrost c Makes sure that the doors close easily and seal well d Make sure the discharge honeycomb and the return grill are free of ice The discharge honeycomb is removable...

Reviews: