P/N 3086855_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
MPCETNM6S
MERCHANDISER ELECTRICAL DATA
Refer to the technical data sheets and merchandiser
serial plate for electrical information.
FIELD WIRING
Field wiring must be sized for component
amperes stamped on the serial plate. Actual
ampere draw may be less than specified.
ELECTRICAL CONNECTIONS
All wiring must be in compliance with NEC
and local codes.
ELECTRICAL OUTLET
Before the merchandiser is connected to any
wall circuit, use a voltmeter to check that the
outlet is at 100% of the rated voltage. The wall
circuit must be dedicated for the merchandis-
er. Failure to do so voids the warranty. Do
not use an extension cord. Never plug in more
than one merchandiser per electrical circuit.
• Always use a dedicated circuit with the
amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit
• Do not use long or thin extension cords.
Never use adapters.
• If in doubt, call an electrician.
Self-contained models have factory-installed
power cords attached at the electrical box.
REFRIGERATION
(Self Contained Models)
Each self contained model is equipped with
its own condensing unit and control panel
located beneath the display area. The correct
type of refrigerant will be stamped on each
merchandiser’s serial plate. The merchan-
diser refrigeration piping is leak tested. The
unit is charged with refrigerant, and shipped
from the factory with all service valves open.
ELECTRICAL / REFRIGERATION
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES
MPCETNM6S
VOLTAGE: 125V / 60 Hz
CONDENSING UNIT:
M6KP-0075-CAA-212
USED WITH KIT #UQ34
MPCETNM6S
VOLTAGE: 125V/250V / 60 Hz
CONDENSING UNIT:
M6GP-H074-CAV-212
USED WITH KIT #US75