17

3. Apply the sanitizing solution according to the

manufacturer’s directions.

4. Rinse thoroughly.

5. Dry completely before resuming operation.

Cleaning Glass and Mirrors

Only use a soft cloth and mild glass cleaner for cleaning 

any glass or mirrored components. Be sure to rinse and/

or dry completely.

User 

I

nformation (Contd)

Never use hot water on cold glass surfaces! it may 

shatter and cause serious injury!

 Allow glass surfaces 

to warm first.

9. Maintenance

Ac

cess Panels

The electrical J box is located in the center of the case 

beneath the plate shelf. The access for condensing units 

(in the self contained units) is located on the side of the 

stand, at the end. Ends of stand are fitted for removal, if 

condensing unit has to be taken out.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL

POWER AT THE MAIN DISCONNECT

WHEN SERVICING OR REPLACING ANY

ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heaters

Thermostats, and Lights.

T-5 Bulbs

T-5 lamps are furnished with a shatterproof protective

coating. The same type of lamp with protective coating

must be used if replaced. All lamps have the label below.

ENCAPSULITE

SHATTERPROOF COATING - SA 10645

Complies with FDA USDA

& OSHA Regulations

for replacement call:

1-800-395-9229

Turn switch off then on after replacing bulb

NSF

U R

R

Evaporator f ans

The evaporator fans are located at the center front of 

these merchandisers directly beneath the display pans. 

Should fans or blades need servicing, always replace 

fan blades with the raised embossed side of the blade 

TOWARD THE MOTOR.

Copper Coils

The copper coils used in Hussmann merchandisers may 

be repaired in the field. Materials are available from local 

refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs. 

Tips and Troubleshooting

 

Before calling for service, check the following:

1. Check electrical power supply to the equipment for

connection.

2. Check fixture loading. Overstocking case will affect

its proper operation.

3. If frost is collecting on fixture and/or product, check

that Humidity Control is working properly, and that

no outside doors or windows are open-allowing

moisture to enter store.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial

Number handy. This information is on a plate

located on the case itself.

Summary of Contents for ISLA IM-FH

Page 1: ...lation Operation Manual Shipped with Technical Data Sheets MANUAL I O ISLA COUNTER CASES ISLA Food Counters IM FR Refrigerated Counters IM FH Hot Counters IM FS Soup Counters P N P N 3034423_C January...

Page 2: ...tions which if not avoided could result in damage to equipment The information contained in this document is the property of Hussmann Corporation and shall not be used in whole or in part without writ...

Page 3: ...r 1 Installation 4 Exterior Loading 4 Bumper Installation 5 Waste Outlet and P Trap 6 Refrigerant Type 6 Piping 6 Control Settings 6 Evaporation Fans 6 Electrical 8 Wiring Color Code 8 Electrical Circ...

Page 4: ...tion within 15 days and retain all packaging The carrier will supply inspection report and required claim forms Shortages Check your shipment for any possible shortages of material If a shortage shoul...

Page 5: ...t safety standards or requirements As clarified by the California State government Proposition 65 can be considered more of a right to know law than a pure product safety law When used as designed Hus...

Page 6: ......

Page 7: ...WELL DATA AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS 240 1 5 1200 240 1 7 5 1800 240 1 10 2400 240 1 12 5 3000 240 1 15 3600 3 2 5 1200 5 0 1200 4 3 7 5 1800 7 5 1800 5 4 10 2400 10 0 2400...

Page 8: ...12 10 2X 25 1 6015 OVERHEAD HEATER DATA AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS 3 94 945 5 65 1355 8 33 2000 10 15 2435 11 75 2820 3 2 3 94 945 4 3 5 65 1355 5 4 5 65 1355 6 5 8 33 200...

Page 9: ...19 0 07 7 5 N A N A N A N A 4 3 2 0 46 36 28 0 26 0 10 10 N A N A N A N A N A 28 0 26 0 10 10 N A N A N A N A 5 4 2 0 46 36 35 0 32 0 12 12 5 N A N A N A N A N A 35 0 32 0 12 12 5 N A N A N A N A 6 5...

Page 10: ...turally designed to support excessive external loading Do not walk on their tops This could cause serious personal injury and damage to the fixture Leveling IMPORTANT it is imperative that the ISLA FO...

Page 11: ...1 Make sure the aluminum channel and end caps are installed Step Use silicone lubricant to help the bumperslide into the channel Step 3 Starting on one end while inserting the bumper push it up again...

Page 12: ...insulation material such as Armstrong s Armaflex b Where condensate drains are located in dead air spaces between refrigerators or between a refrigerator and a wall provide means to prevent freezing...

Page 13: ...al raceway or under the case Thermostatic Expansion Valve Location This device is located on the same side as the refrigeration stub A Sporlan balanced port expansion valve model is furnished as stand...

Page 14: ...igh wattage appliances It should be wired to a dedicated circuit Electrical service Receptacles When a pplicable The receptacles located on the exterior of the merchandiser are intended for scales and...

Page 15: ...ature requirements Critical attention must be given to the heat controls for these hot tables soup bars Both the upper and lower heat controls soup only require lower control must be adjusted to achie...

Page 16: ...1919 Mexico 1 800 890 2900 www hussmann com 13 Startup To fill the well Turn the fill valve to open position Close the drain valve To drain the well Turn the fill valve to the closed position Open th...

Page 17: ...D COUNTERS 14 Operation Turn power switch on Set temperature control to 7 setting Adjust as necessary Adjust overhead heater as necessary Shutting down Turn ON switch off Close fill valve Open drain v...

Page 18: ...hould be cleaned thoroughly and frequently The interior may be cleaned with any domestic soap or detergent based cleaners Sanitizing solutions will not harm the interior bottom however these solutions...

Page 19: ...rate a minimum of 6 hours before stocking with any product 5 When stocking never allow the product to extend beyond the recommended load limit Air discharge and return air flue must be unobstructed at...

Page 20: ...ting The same type of lamp with protective coating must be used if replaced All lamps have the label below ENCAPSULITE SHATTERPROOF COATING SA 10645 Complies with FDA USDA OSHA Regulations for replace...

Page 21: ...des ask for an alternative Also avoid cleaners containing quaternary salts as they also can attack stainless steel cause pitting and rusting 4 Treat your Water Though this is not always practical soft...

Page 22: ...k defrost settings See Technical Specifications section Product load may be over its limits blocking airflow Redistribute product so it does not exceed load level There is a sticker on the inside of t...

Page 23: ...s freezing over Return air is blocked make sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Large gap is visible o...

Page 24: ...and call Hatco to replace if necessary Faulty control Check and call Hatco to replace if necessary Losse wiring on heater Check wiring electrical connections Temperature setting Off Increase shelf hea...

Page 25: ...ing equipment caused by liming sediment buildup chemical attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMED...

Page 26: ...___________ ______________________________________________________________________________________________ _______________ _____________________________________________________________________________...

Reviews: