LEVELING
The refrigerator must be level to insure proper operation of the refrigeration system and to
insure proper drainage of defrost water. Use the leveling shims provided to level the case with
the aid of a carpenter’s level. Leveling must be performed from front-to-back and from side-to-
side.
WASTE OUTLET and WATER SEAL
The waste outlet, for all models, is located in the centre of the case. The outlet has a factory
installed, external water seal.
•
On self-contained models………This water seal is formed by a moulded trap that drains into
the condensate evaporation pan located beneath the case.
•
On remote models…………….. This water seal is formed by a moulded trap that requires
drip piping to connect with floor drain. The case is
equipped with a 1.5” female N.P.T. for field installation.
SEALING CASE TO FLOOR
If required by local sanitary codes or if customer desires, case may be sealed to the floor using a
vinyl cove base trim. The size needed will depend on how much variation there is in the floor,
from one end of the case to the other. Sealing of the lower front and rear panels on self-
contained models may hamper their removal for servicing or maintenance of the condensing
unit.
CAUTION:
DO NOT ALLOW SEALING TRIM TO COVER ANY INTAKE OR
DISCHARGE GRILLS LOCATED IN THE LOWER FRONT PANEL.