SERIAL PLATE AMPERAGES
Serial plate amperes are the amperage figures that are stamped on the fixture’s Serial Plate. Although all
field-installed wiring must be sized to the Serial Plate amperages, the actual current or amps may be less
than specified. (Serial Plate is located on panel of the product display area.)
SELF CONTAINED MODELS
(Standard Configuration)
CIRCUIT REQUIREMENTS
MODEL
Power Supply
MCA
Minimum Circuit Ampacity
Of Serial Plate
ISM / G / G – 5B
120V, 60Hz, 1
∅
12.2 amps
ISF / G / G – 5B
120V, 60Hz, 1
∅
18.3 amps
ISM / G / G – 8B
120V, 60Hz, 1
∅
-
ISF / G / G – 8B
120V, 60Hz, 1
∅
16.2 amps
ISM / G / G – 10B
120V, 60Hz, 1
∅
-
ISF / G / G – 10B
120V, 60Hz, 1
∅
-
ISM / G / G - 5 D / G
208 - 230v, 60 Hz, 1
∅
-
ISF / G / G - 5 D / G
208 - 230v, 60 Hz, 1
∅
11.1 amps
ISM / G / G - 8 D / G
208 - 230v, 60 Hz, 1
∅
-
ISF / G / G - 8 D / G
208 - 230v, 60 Hz, 1
∅
16.5 amps
ISM / G / G - 10D / G
208 - 230v, 60 Hz, 1
∅
-
ISF / G / G - 10 D / G
208 - 230v, 60 Hz, 1
∅
-
ISM / G / G - 5K
208 - 230v, 60 Hz, 3
∅
11.1 amps
ISF / G / G - 5K
208 - 230v, 60 Hz, 3
∅
-
ISM / G / G - 8K
208 - 230v, 60 Hz, 3
∅
-
ISF / G / G - 8K
208 - 230v, 60 Hz, 3
∅
-
ISM / G / G - 10K
208 - 230v, 60 Hz, 3
∅
-
ISF / G / G - 10K
208 - 230v, 60 Hz, 3
∅
-
CircuitAmpacity
Circuit ampacity is calculated by the summation of the following
connected items; which may include but is not limited to.
Anti-short heaters, electric fans, electric defrost heaters, condensing unit, condensate heater, electric
defrost heaters, canopy and shelf lighting.