background image

7 of 8

P/N 0473381_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

5

4

5

5

5

5

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Five Rows of Shelves

4 ft case

Connector

5

4

5

5

5

5

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

5

4

5

5

5

5

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

BL

R

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Summary of Contents for impact Excel C5X-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Page 2: ...24 612 24 612 24 612 24 612 Length of electrical wireway 26 1 2 673 26 1 2 673 26 1 2 673 26 1 2 673 C RH End of case to LH end of wireway 42 1 8 1070 66 1 8 1680 90 1 8 2289 138 1 4 3511 Waste Outlet...

Page 3: ...4 F 17 F 7 F 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C5X E 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5...

Page 4: ...Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8...

Page 5: ...ft 0 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 44 ft2 ft 1 35 m2 m Shelf Area 4 Sq Ft Ft 9 88 ft2 ft 3 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Leng...

Page 6: ...tor 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING...

Reviews: