background image

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

800 (363)

1000 (454)

1200 (544)

1400 (635)

100 (45)

5

Actual weights will vary according to optional kits included.

5 of 8

P/N 0473381_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

C5X-E

Meat, Produce, Dairy &

Delicatessen

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

11.71 ft

3

/ft  (1.09 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

9.39 ft

/ft  (0.87 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

4.44 ft

2

/ft  (1.35 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

9.88 ft

2

/ft  (3.01 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (4) rows of 22-inch shelves.

eparately from

fans.

Summary of Contents for impact Excel C5X-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Page 2: ...24 612 24 612 24 612 24 612 Length of electrical wireway 26 1 2 673 26 1 2 673 26 1 2 673 26 1 2 673 C RH End of case to LH end of wireway 42 1 8 1070 66 1 8 1680 90 1 8 2289 138 1 4 3511 Waste Outlet...

Page 3: ...4 F 17 F 7 F 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C5X E 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5...

Page 4: ...Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8...

Page 5: ...ft 0 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 44 ft2 ft 1 35 m2 m Shelf Area 4 Sq Ft Ft 9 88 ft2 ft 3 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Leng...

Page 6: ...tor 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING...