background image

7 of 8

P/N 0457232C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

SHELF CONFIGURATION

This merchandiser is designed for
one, two or three shelves.

The depth of the shelf used in the
top eight (8) shelf hole locations
is critical to case performance.

If a shelf is placed in one of the
top eight (8) locations it must
comply with the angle/depth
requirements listed below.  

Maximum Shelf

Shelf Angle

Depth

0 º

12 in.

15 º

14 in.

or less

30 º

18 in.

or less

45 º

18 in.

or less

NOTE:

Shelves placed in the

lower positions may be up to 
18 in. deep when positioned 
at a 0 º angle.

Top Eight (8)
Shelf Hole
Locations

18 in.

18 in.

14 in.

12 in.

15°

30°

45°

Angle

Maximum

Shelf

Size

18 in.

Impact  

C2-XLGEP

Dairy / Delicatessen 

Precut & Packaged Produce

Summary of Contents for Impact Excel C2X-LGEP

Page 1: ... ASSEMBLIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item HEATERS C Canopy Anti Sweat Heater 3 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS D Ballast Electronic 4 0376409 2 lamps 0376410 3 lamps E Fluorescent Lamp 5 Replace wit...

Page 2: ...1 2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between front skid rail and splashguard 7 3 4 199 7 3 4 199 7 3 4 199 7 3 4 199 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 38 1 4 972 64 3 8 16...

Page 3: ...SIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0457232C HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Optional Accessory Items 19 48...

Page 4: ...2 70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 ...

Page 5: ...ERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G...

Page 6: ...Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS ...

Page 7: ...s placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when positioned at a 0 º angle Top Eight 8 Shelf Hole Locations 18 in 18 in 14 in 12 in 0 15 30 45 Angle Maximum Shelf Size 18 ...

Page 8: ...elf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the canopy by pulling it forward 3 Remove the top panel by lifting it up 4 Service or replace ballasts as required 5 Reassemble items as they were originally installed NOTE Rail lamp ballast is located behind ...

Reviews: