Hussmann D5XEE Technical Data Sheet Download Page 6

4

4

5

5

5

5

Optional 

Two Row 

Canopy

Connector

BL

W

BL

G

W

R

R

R

BL

BL

R

R

R

B

B

Orange or Tan Band

Standard Lighting 

 1 Row Canopy 

 Optional Lighting 

 2 Row Canopy

4

5

5

Connector

W

B

BL

BL

R

R

R

 Optional Lighting 

 1 Row Rail

B

2

Defrost 

Termination 

Thermostat

Refrigeration 

Thermostat

Dark Blue

To 
Condensing 
Unit

}

Light Blue

3

2 Fans

B

ROWN

  B

AND

120V 

P

OWER

Fans

1

B

ROWN

  B

AND

120V 

N

EUTRAL

Fan Wiring
Offtime Defrost

Light Circuits

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

=  Case G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

6 of 9

D5XELE / D5XEE 

Technical Data Sheet

Summary of Contents for D5XEE

Page 1: ...sembly 1 0477655 Fan Motor Evaporator MO 4410546 0461805 Fan Blade FB 4780446 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermost...

Page 2: ...pipe 1 1 4 32 Refrigeration Outlet Back of case to center of refrigeration outlet 31 5 8 803 LH end of case to center of refrigeration outlet 71 1 2 1816 2 of 9 HUSSMANN CORPORATION Bridgeton MO 6304...

Page 3: ...VENTIONALCONTROLS Low Pressure Backup Control D5XELE D5XEE CI CO Temp Deg F 17 7 17 7 Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine...

Page 4: ...fficient 0 50 0 50 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 51 0 77 59 59 Optional Lighting T 8 fluorescen...

Page 5: ...0 69 m3 m ARI Total Display Area 3 Sq Ft Ft 4 86 ft2 ft 1 48 m2 m Shelf Area 4 Sq Ft Ft 7 81 ft2 ft 2 38 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length...

Page 6: ...Thermostat Dark Blue To Condensing Unit Light Blue 3 2 Fans BROWN BAND 120V POWER Fans 1 BROWN BAND 120V NEUTRAL Fan Wiring Offtime Defrost Light Circuits R Red Y Yellow G Green BL Blue B Black W Whit...

Page 7: ...L R BL R BL W R W R B R BL BL R 4 B BL BL BL BL BL R R R R R 5 4 5 5 5 5 BL BL R BL R BL R BL W R W R B R BL BL R 4 B BL BL BL BL BL R R R R R R Red Y Yellow G Green BL Blue B Black W White 120V POWER...

Page 8: ...BL 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground...

Page 9: ...ptacle B Connector R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V...