Hussmann D5XEE Technical Data Sheet Download Page 5

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

800 (363)

1000 (454)

1200 (544)

1400 (635)

100 (45)

5

Actual weights will vary according to optional kits included.

5 of 9

P/N 0481484_A

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

D5XELE / D5XEE

Dairy & Delicatessen

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

11.71 ft

3

/ft  (1.09 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

7.42 ft

/ft  (0.69 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

4.86 ft

2

/ft  (1.48 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

7.81 ft

2

/ft  (2.38 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product 

Reference Guide

. The standard shelf complement for this model is (4) rows of 16-inch shelves.

eparately from fans.

Summary of Contents for D5XEE

Page 1: ...sembly 1 0477655 Fan Motor Evaporator MO 4410546 0461805 Fan Blade FB 4780446 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermost...

Page 2: ...pipe 1 1 4 32 Refrigeration Outlet Back of case to center of refrigeration outlet 31 5 8 803 LH end of case to center of refrigeration outlet 71 1 2 1816 2 of 9 HUSSMANN CORPORATION Bridgeton MO 6304...

Page 3: ...VENTIONALCONTROLS Low Pressure Backup Control D5XELE D5XEE CI CO Temp Deg F 17 7 17 7 Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine...

Page 4: ...fficient 0 50 0 50 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 51 0 77 59 59 Optional Lighting T 8 fluorescen...

Page 5: ...0 69 m3 m ARI Total Display Area 3 Sq Ft Ft 4 86 ft2 ft 1 48 m2 m Shelf Area 4 Sq Ft Ft 7 81 ft2 ft 2 38 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length...

Page 6: ...Thermostat Dark Blue To Condensing Unit Light Blue 3 2 Fans BROWN BAND 120V POWER Fans 1 BROWN BAND 120V NEUTRAL Fan Wiring Offtime Defrost Light Circuits R Red Y Yellow G Green BL Blue B Black W Whit...

Page 7: ...L R BL R BL W R W R B R BL BL R 4 B BL BL BL BL BL R R R R R 5 4 5 5 5 5 BL BL R BL R BL R BL W R W R B R BL BL R 4 B BL BL BL BL BL R R R R R R Red Y Yellow G Green BL Blue B Black W White 120V POWER...

Page 8: ...BL 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground...

Page 9: ...ptacle B Connector R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V...

Reviews: