D5X-RE 

Technical Data Sheet 

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

8 of 10

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

7

7

7

7

7

7

7

R

BL

6

B

B

W

W

BL

R

G

4 ft case

6 ft or 8 ft case

12 ft case

(TYP)

Shelf Light

Plug & Receptacle

B

Connector

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

7

7

7

7

7

7

7

R

BL

6

B

B

W

W

BL

R

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

7

7

7

7

7

7

7

R

BL

6

B

B

W

W

BL

R

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

W

Connector

Optional Shelf Harness and LED Light Circuits for 
 
 
3, 4, 5, 6 & 7 Rows of Shelves

Optional Shelf Lighting
LED Fixtures

Summary of Contents for D5X-RE

Page 1: ...676 0480131 3 lamps BA 4481654 0480132 4 lamps BA 4481677 E Fluorescent Lamp 5 Replace with like fixtures F 0501213 Power Supply EP 4481861 6 G LED Fixture 7 Replace with like fixtures D5X RE Technica...

Page 2: ...upport 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Distance between front skid rail and splashguard 6 152 6 152 Electrical Service Electrical Field Wiring connection p...

Page 3: ...F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D5X RE 8 ft 2 7 12 ft 3 9 This is an average for all refrig...

Page 4: ...V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting Additional 1 Row Canopy 0 51 0 77 59 85 Additional 2 Row Canopy 1 02 1 54 118 170 Ad...

Page 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 4 58 ft2 ft 1 40 m2 m Shelf Area 4 Sq Ft Ft 7 87 ft2 ft 2 40 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m...

Page 6: ...nector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft Defrost Termination Thermostat Refrigeration Thermostat Dark Blue 3 To Condensing Unit Light...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Page 9: ...ed Doors Fully Closed Double walled telescoping doors slide both left and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Dair...

Page 10: ...to the cooler Rear View of 12 Foot Dairy Merchandiser 23 3 4 130 1 4 37 3 4 67 1 2 79 1 2 23 3 4 D o o r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide...

Reviews: