background image

9

Refrigeration

Refrigerant Type

Unless otherwise speci! ed on the factory order, remote and 
self-contained merchandisers are equipped for operation 
on R22 refrigerant. The correct type of refrigerant will be 
stamped on each merchandiser’s serial plate located inside 
the merchandiser.

Refrigeration Piping

 Liquid

Suction

3/8" O.D.

5/8" O.D. 

The  refrigerant  line  connections  are  behind  the  rear 
close-off panel, underneath the drain tub, on the left hand 
end  of  the  merchandiser  as  viewed  from  the  rear. After 
connections have been made, seal this outlet thoroughly. 
Seal both inside and the outside. We recommend using an 
aerosol dispensed urethane type of insulation. See SHVS 
technical  data  sheet  for  proper  duration  and  frequency. 
Self contained cases have individual defrost time clocks. 
When power has been applied, set the time clock to the 
proper duration and frequency.

The time clock is located behind the front panel under the 
case. Turn the clock dial counterclockwise until the pointer 
is directed to the current time of day.

Multiplexing -

 Piping of merchandisers operating on the 

same refrigeration system may be run from merchandiser 
to merchandiser through the end frame saddles provided 
for  this  purpose. 

DO  NOT  RUN  REFRIGERANT  LINES 

THROUGH  MERCHANDISERS  THAT  ARE  NOT  THE 
SAME REFRIGERATION SYSTEM

 as this may result in 

poor refrigeration control and compressor failure.

Line Sizing -

 Refrigerant lines should be sized as shown 

on the refrigeration legend that is furnished for the store 
(not  furnished  by  Hussmann).  If  a  legend  has  not  been 
furnished, refer to the Hussmann Application Engineering 
Manual for guidance.

Oil Traps -

 P-TRAPS (oil traps) must be installed at the 

base of all suction line vertical risers.

Pressure  Drop  -

  Pressure  drop  can  rob  the  system  of 

capacity. To keep the pressure drop to a minimum, keep the 
refrigerant line run as short as possible using a minimum 
number of elbows. Where elbows are required, use long 
radius elbows only.

I

nsulation - 

The suction and liquid lines should be clamped 

or taped together and insulated for a minimum of 30’ from 
the merchandiser. Additional insulation is recommended 
wherever condensation drippage is objectionable.

Refrigeration Data

Note:  

This data is based on store temperature and humidity 

that does not exceed 75F and 55% R.H.

Note:  

Not recommended to control temp by regulating coil 
temp allow T-STAT to cycle and control temp.

Btu/hr/ft* 

See Spec Sheets

*For all refrigeration equipment other than Hussmann, use 
conventional Btu values.

 

  

ELECTRIC or GAS Not Recommended

Physical Data

Merchandiser Drip Pipe (in.)  

 

Merchandiser Liquid Line (in.)    

3/8*

Merchandiser Suction Line (in.)   

5/8*

Estimated Charge (lb)***

4ft 

1.2 

5ft 

1.5 

6ft 

1.8

*Dependent on case length and refrigerant type.

***  This  is  an  average  for  all  refrigerants  types. Actual 
refrigerant  charge  may  vary  by  approximately  half  a 
pound.

Glycol Requirements

GPM 

PSI

4ft 

0.8

2.3

5ft 

1.0

3.3

6ft 

1.2

5.2

Summary of Contents for Chino SHVS Series

Page 1: ...SHVS SUMMIT HIGH VOLUME SERVICE BAKERY CASE INSTALLATION OPERATION GUIDE CHINO SHVS SUMMIT HIGH VOLUME SERVICE BAKERY CASE REV 0317 Installation Operation Manual ...

Page 2: ...ummit High Volume Bakery Case with 4 levels 3 shelves and lift front glass Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe arrival If damaged either apparent or concealed claim must be made to the carrier Apparent Loss or Damage ...

Page 3: ...turnover and require no refrigeration The SHVS R and SHVS S C refrigerated bakery merchandisers are designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75 F dry bulb temperature and 55 relative humidity Review the SHVS Technical Data Sheet to verify thermostat setting Do not set temperature too cold as this causes product dehydration Defrost cy...

Page 4: ...nel Step 3 Starting on one end while inserting the bumper push it up against the end cap to prevent the bumper from shrinking after installation when it gets cold Step 4 As you insert the bumper into the channel with one hand pull the bumper toward you with the other to open the inside lips Slowly apply pressure by rolling the bumper into the track Installation Cont d ...

Page 5: ...nstalling Over cut the flexible vinyl and compression fit Adding the additional materials will compensate for stretching which occurs during installation Installation Cont d Boston 2000 Eco Series 1 Attach the base and end corner cap to the desired surface by inserting 8 pan head screws through the pre slotted holes in both the end cap and the base Insert screws through the two holes of end cap an...

Page 6: ... that vinyl legs are positioned within the base grooves Roll vinyl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid Top over the Rigid Base 3 If necessary wipe clean with any household cleaning product Helpful Hints For best results before cutting install a scrap piece of base into vinyl top to achieve a clean cut...

Page 7: ...el to ensure proper operation of the refrigeration system and to ensure proper drainage of defrost water Place prybar under metal base and lift DO NOT LIFT END PANEL Turn leveler with supplied wrench one wrench per order clockwise to raise counter clockwise to lower Repeat process with other levelers until case is level NOTE To avoid removing concrete ooring begin lineup leveling from the highest ...

Page 8: ...aller than the nominal diameter of the pipe or water seal supplied with the merchandiser 2 When connecting drip piping the water seal must be used as part of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe Double water seals in series will cause an air lock and prevent draining 3 Pitch the drip piping in the direction of ow There s...

Page 9: ...trol and compressor failure Line Sizing Refrigerant lines should be sized as shown on the refrigeration legend that is furnished for the store not furnished by Hussmann If a legend has not been furnished refer to the Hussmann Application Engineering Manual for guidance Oil Traps P TRAPS oil traps must be installed at the base of all suction line vertical risers Pressure Drop Pressure drop can rob ...

Page 10: ...f life Not complying with these instructions will increase spoilage rate due to drying of the product and could cause sweating on the front glass if operated too cold Allow bakery products to reach store ambient conditions after preparation just prior to display This is essential to maximize the shelf life of perishables ...

Page 11: ...surfaces may be cleaned with most domestic detergents ammonia based cleaners and sanitizing solutions with no harm to the surface Shut off fan during cleaning Important Steps 1 For temperature settings please see the SHVS technical data sheet 2 Temperature control should be my means of a T STAT and Suction Solenoid or equivalent for each case 3 Product should be worked and rotated on a regular bas...

Page 12: ... of the manufacturer s polishing marks 2 Clean With the Polish Lines Some stainless steels come with visible polishing lines or grain When visible lines are present you should ALWAYS scrub in a motion that is parallel to them When the grain cannot be seen play it safe and use a soft cloth or plastic scouring pad 3 Use Alkaline Alkaline Chlorinated or Non chloride Containing Cleaners While many tra...

Page 13: ...compliance with NEC and local codes All electrical connections for the nonrefrigerated model are to be made in the electrical panel Electrical connections for refrigerated models are made in the electrical box on the back of the case behind the rear close off panel Field Wiring Field wiring must be sized for components amperes stamped on the serial plate Actual ampere draw may be less than speci e...

Page 14: ...AN MOTOR CB CB CB REVISION HISTORY NOTES CASE MUST BE GROUNDED WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED B SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 2 2 120V BUNDLE BROWN M M BLK 14 WHITE 14 LIGHT SWITCH 00001258 AIR SWEEP FAN MOTOR 2 0522287 4 4W 15A 120VAC M BUNDLE BROWN M M BLK 14 WHITE 14 EVAP FAN MOTOR 3 0522287EF 4 4W 15A 120VAC BUNDLE ORANGE 120 VAC 60 Hz BLK 14 L1 N MCA 41A MOP...

Page 15: ...REVISION HISTORY NOTES CASE MUST BE GROUNDED WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED B SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 2 2 120V BUNDLE BROWN M M BLK 14 WHITE 14 LIGHT SWITCH 00001258 AIR SWEEP FAN MOTOR 2 0522287 4 4W 15A 120VAC M BUNDLE BROWN M M BLK 14 WHITE 14 EVAP FAN MOTOR 3 0522287EF 4 4W 15A 120VAC BUNDLE ORANGE 120 VAC 60 Hz BLK 14 L1 N MCA 41A MOP 15A WHT 14 CANOPY...

Page 16: ... EVAP FAN MOTOR CB CB CB REVISION HISTORY NOTES CASE MUST BE GROUNDED WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED B SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 2 8 120V BUNDLE BROWN M M BLK 14 WHITE 14 LIGHT SWITCH 00001258 AIR SWEEP FAN MOTOR 2 0522287 4 4W 15A 120VAC M BUNDLE BROWN M M BLK 14 WHITE 14 EVAP FAN MOTOR 4 0522287EF 4 4W 15A 120VAC BUNDLE ORANGE 120 VAC 60 Hz BLK 14 L1 N MCA ...

Page 17: ... 14 LIGHT SWITCH 00001258 AIR SWEEP FAN MOTOR 2 0522287 4 4W 15A 120VAC M BUNDLE BROWN M M BLK 14 WHITE 14 EVAP FAN MOTOR 3 0522287EF 4 4W 15A 120VAC BUNDLE ORANGE 120 VAC 60 Hz BLK 14 L1 N MCA 41A MOP 15A WHT 14 CANOPY LIGHT CIRCUIT 33A 35 2W 3 LED LIGHT LED DRIVER 120 VAC 60 Hz MCA 38A MOP 15A 120 VAC 60 Hz MCA 60A MOP 15A 4 LED LIGHT 4 LED LIGHT 4 LED LIGHT SHELF LIGHTS BUNDLE BROWN M M BLK 14 ...

Page 18: ...TOR 3 0522287EF 4 4W 15A 120VAC BUNDLE ORANGE 120 VAC 60 Hz BLK 14 L1 N MCA 41A MOP 15A WHT 14 CANOPY LIGHT CIRCUIT 33A 35 2W 3 LED LIGHT LED DRIVER 120 VAC 60 Hz MCA 3 9A MOP 15A 120 VAC 60 Hz MCA 38A MOP 15A 120 VAC 60 Hz MCA 60A MOP 15A 4 LED LIGHT 4 LED LIGHT 4 LED LIGHT SHELF LIGHTS BUNDLE BROWN M M BLK 14 WHITE 14 LIGHT SWITCH 00001258 AIR SWEEP FAN MOTOR 2 0522287 4 4W 15A 120VAC M BUNDLE B...

Page 19: ...19 0 1 1 2 1 3 43 3 1 3 2 2 5 1 1 1 6 1 6 Specification Sheet ...

Page 20: ...ld perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to manufacturer s recommendations b Observation of outside in uences such as drafts radiant heating from the ceiling and from lamps Such in uence should be properly corrected or compensa...

Page 21: ...owing 1 Has the refrigerator been loaded with warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air ow and mixing with room air 6 Are spotlights or other high intensity lighting directed onto the product 7 Are there unusual draft conditions from heating air condition...

Page 22: ...c Expedite perishables to the store s storage equipment to avoid unnecessary warm up and prolonged temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas e Display and stor...

Page 23: ... more of a right to know law than a pure product safety law When used as designed Hussmann believes that our products are not harmful We provide the Proposition 65 warning to stay in compliance with California State law It is your responsibility to provide accurate Proposition 65 warning labels to your customers when necessary For more information on Proposition 65 please visit the California Stat...

Page 24: ..._____________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _________...

Reviews: