BEFORE SERVICING

Always disconnect electrical power at the main 

disconnect when servicing or replacing any

electrical component.

This includes (but not limited to) Fans, Heaters,

Thermostats and Lights.

Replacing Fluorescent Lamps

Fluorescent  lamps  are  furnished  with  a  shatterproof 

protective coating. The same type of lamp with protective 

coating must be used if replaced. 

T-5 Bulbs

Please note: T-5 lights must be turned off and on after bulb 

replacement.

This lamp has been treated to resist breakage and must be 

replaced with a similarly treated lamp in order to maintain

compliance with NSF Standards. 

NSF CODE 4.28.1

Contact HUSSMAN Chino for replacement.

1-800-395-9229 X 2131

evaporator Fans

The evaporator fans are located at the center front of these 

merchandisers directly beneath the display pans. Should fans 

or blades need servicing, always replace fan blades with the 

raised embossed side of the blade 

TOWARD THE MOTOR.

Copper Coils

The copper coils used in Hussmann merchandisers may 

be repaired in the field. Materials are available from local 

refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

Tips and Troubleshooting

Before calling for service, check the following:

1.   Check electrical power supply to the equipment for 

connection.

2.   Check fixture loading. Overstocking case will affect 

its proper operation.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial

Number handy. This information is on a plate

located on the case itself.

                          

CLEANING PRECAUTIONS

When cleaning:

• Do not use high pressure water hoses

• Do not introduce water faster than waste outlet can drain

• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN

• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL 

   BASE (these will dissolve the butyl sealants) or an AMMONIA BASE 

    (this will corrode the copper componets of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY

• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS  

   (these will mar the finish)

plexiglass and Acrylic Care

Improper cleaning not only accelerates the cleaning cycle 

but also degrades the quality of this surface. Normal daily 

buffing motions can generate static cling attracting dust to 

the surface. Incorrect cleaning agents or cleaning cloths 

can  cause  micro  scratching  of  the  surface,  causing  the 

plastic to haze over time.

Cleaning

Hussmann recommends using a clean damp chamois, or a 

paper towel marketed as dust and abrasive free with 

210

®

 

plastic Cleaner and polish

 available by calling Sumner 

Labs at 

1-800-542-8656

. Hard, rough cloths or paper towels 

will scratch the acrylic and should not be used.

Antistatic Coatings

The 

210

®

  has  proven  to  be  very  effective  in  not  only 

cleaning  and  polishing  the  Plexiglass  surface,  but  also 

providing anti-static and anti-fog capabilities. This product 

also seals pores and provides a protective coating.

Installing perimeter plexiglass

1.   If necessary, remove Boston cart bumper

.   Loosen screws holding Boston onto case. If a piece 

of front plexiglass has to be removed, gently slide it 

upwards taking care not to damage foam located on 

inside of glass.

Maintenance

User Information (Cont'd)

Summary of Contents for CHINO CIDM-E

Page 1: ...CIDM E CIDM I p n IGIC CIDM 0508 INSTALLATION OPERATION GUIDE CHINO CIDM E I Rev 0508 Installation Operation Manual...

Page 2: ...ains Information on CIDME CIDMI Refrigerated Self Service Island Display including 4 Crown and 3 Center Modules available as standard refrigerated med temp Shipping Damage All equipment should be thor...

Page 3: ...Plan Views 29 1 2 6 9 19 5 16 6 3 16 2 7 8 11 3 11 16 40 13 16 48 3 16 CIDM ISLAND 3 11 16 CIDME 34 7 8 3 1 16 12 13 16 27 36 33 30 3 8 10 Elec Elec Elec Ref 26 1 8 25 1 8 23 1 16 21 1 8 23 1 8 Ref D...

Page 4: ...hen cases are joined in the field When joining use a carpenters level and shim legs accordingly Case must be raised correctly under legs where support is best to prevent damage to case 1 Check level o...

Page 5: ...and product losses Please follow the recommendations listed below when installing condensate drains to insure a proper installation 1 Never use pipe for condensate drains smaller than the nominal dia...

Page 6: ...Access to TX Valves and Drain Lines Mechanical Remove product from end of case Remove product racks Remove refrigeration and drain access panels labeled TX valve mechanical only and drain are located...

Page 7: ...s provided on the exterior back of these models is intended for computerized scales with a five amp maximum load not for large motors or other high wattage Finishing Touches Plexiglass Joining Instruc...

Page 8: ...V H O will shorten the shelf life of the product Case Cleaning Long life and satisfactory performance of any equipment are dependent upon the care given to it To insure long life proper sanitation an...

Page 9: ...ocated on the case itself CLEANING PRECAUTIONS When cleaning Do not use high pressure water hoses Do not introduce water faster than waste outlet can drain NEVER ONASELF CONTAINED UNIT WITHAN EVAPORAT...

Page 10: ...DM CIDME 4 X3 W0300006 CIDME w OMNISTAT W0300008 CIDMI 3 W0300007 CIDMI 3 w OMNISTAT W0300009 CIDM I R 14 W0300017 CIDM I SC 14 W0300018 CIDM I R Hot Gas 14 W0300019 CIDM I R Hot Gas 10 W0300020 CIDM...

Page 11: ...FAN H4 H2 H3 H1 L2 ZONE SENSOR IS LOCATED BEHIND THE TOP FRONT DISCHARGE AND IS ATTACHED TO THE FRONT CAD SUPPORT STANDARD EVAP SENSOR IS LOCATED ON THE SECOND RUN OF THE COIL COMING AWAY FROM THE CAD...

Page 12: ...OMNI STAT PN952911 230VAC POWER SUPPLY 230 Vac PROD TEMP AIR TEMP L 9 1 2 3 4 5 6 7 8 CONDENSING UNITS COPELAND F9AM A103 CFV 140 1 H P R 22 RLA 9 5 1857W MCC 13 7 LRA 43 3 225 03 0121 1 R CONDENSING...

Page 13: ...T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 208 240 VAC 60 Hz L1 ZONE EVAP DEF COMM COMP ALARM FAN H4 H2 H3 H1 L2 ZONE SENSOR IS LOCATED BEHIND THE TOP FRONT DISCHARGE AND IS ATTACHED TO THE FRO...

Page 14: ...MCC 13 7 LRA 43 3 225 03 0121 1 R CONDENSING UNIT M M LIGHT CIRCUIT 93A 100W M CRTL PRSR DUAL 225 01 0706B BLK 14 RED 14 WHT 14 WHT 14 RED 14 BLK 14 RED 14 MCA 7 8A MOP 15A SAFETY SWITCH FLOAT SWITCH...

Page 15: ...2 F25 T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 F25 T8 SPX30 2 125 03 1072 M M M EVAP FAN MOTORS 2 9W CW 125 01 3076 TERMINAL BLOCK 125 01 0295 BLUE WHITE 115 V L1 2 6 L2 L3 208 V 17 5 17 5 24...

Page 16: ...W BROWN BROWN CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE WHITE BLACK BROWN BROWN BROWN BROWN YELLOW YELLOW RED RED BLUE WHITE BLUE WHITE BLUE BLUE BALLAST 125 01 3273 MAGNETE B432PUNVHP A BAL...

Page 17: ...B432PUNVHP A BLUE BLUE BLUE WHITE BLUE WHITE RED RED YELLOW YELLOW BROWN BROWN BROWN BROWN BLACK WHITE F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 125 03 0007 F15 T8 SPX30 2 1...

Page 18: ...W BROWN BROWN CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE CAP OFF WIRE WHITE BLACK BROWN BROWN BROWN BROWN YELLOW YELLOW RED RED BLUE WHITE BLUE WHITE BLUE BLUE BALLAST 125 01 3273 MAGNETE B432PUNVHP A BAL...

Page 19: ...F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F17T8 24 125 03 1071 F32T8 48 125 03 1073 F32T8 48 1...

Page 20: ...5 03 1073 M M M 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 BLACK WHITE M FAN MOTORS 4 9W CW 00001212 F15T8 18 125 03 1075 F15T8 18 125 03 1075 F15T...

Page 21: ...18 07 CIDM W0300021 CIDM E R EVAP FAN MOTORS 2 125 01 0615A 6A 49W 120VAC LIGHT SWITCH TOGGLE 125 01 0307 INSIDE PERIMETER LIGHTS 2 125 03 1075 F15 T8 SPX30 OUTSIDE PERIMETER LIGHTS 4 125 03 1071 F17...

Page 22: ...MCA 65A MOP 15A L1 N BLK 14 WHT 14 TAG ORANGE BLK 14 WHT 14 TAG BROWN BALLAST 125 01 3266 FULHAM LH3 120 L INCOMING POWER 120 VAC 60 Hz GFCI DUPLEX 125 01 3178 BLK NOTE FOR GFCI PROTECTION IF MORE THA...

Page 23: ...t after control Switch On or from digital input A4 or A5 4 C 0 199 min 0 0 d6 Block temperature display during defrost 0 no 1 yes C 0 1 flag 1 1 dd Dripping time after defrost F 0 15 min 2 0 d8 Alarm...

Page 24: ...POINT desired temperature value Press the SET button for one second to display the Set Point value After few seconds the set value blinks Press UP or DOWN to increase or decrease the set point value p...

Page 25: ...with normal refrigeration practices Refrigeration piping should be insulated according to Hussmann s recommendations 1 3 A clogged waste outlet blocks refrigeration The installer is responsible for th...

Page 26: ...arge opening c READING It should first be determined that the refrigerator is refrigerating and has operated at least one hour since the end of the last defrost period The thermometer reading should b...

Page 27: ...hese rules a Buy quality products b Receive perishables from transit equipment at the ideal temperature for the particular product c Expedite perishables to the store s storage equipment to avoid unne...

Page 28: ...________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________...

Reviews: