background image

C2-LE 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

8 of 8

R e m o v e

S c r e w s

Remove Screws

B a l l a s t

C a n o p y   T o p   P a n e l

Impact  

C2-LE

Dairy / Delicatessen 
Precut & Packaged Produce

Foil-covered 
Anti-sweat 
Heater

Canopy

Canopy

Anti-Sweat Heater Wires 
with Purple Markers

Electrical 
Wireway

CANOPY AND SHELF LAMP BALLAST

The ballast for the canopy and shelf lamps is located
behind the canopy on the left-hand end (when facing
case) of the merchandiser.  

To access the ballast:
1. Remove screws at bottom edge of canopy and rear

of top panel.

2. Remove the one piece canopy top panel by moving

panel forward slightly to clear flange in front then
lifting up.

3. Service or replace ballasts as required.

4. Reassemble items as they were originally installed.

NOTE

:  Rail lamp ballast is located behind the lower

front panel.

CANOPY ANTI-SWEAT HEATER

The canopy anti-sweat heater location is shown below.
Connections are in the Electrical wireway.

Summary of Contents for C2-LE

Page 1: ...ion Thermostat Item Part Description Wiring Item HEATERS D Canopy Anti Sweat Heater 4 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS E Ballast Electronic 5 0376409 2 lamps 0376410...

Page 2: ...kout 38 1 4 972 64 3 8 1635 88 3 8 2245 136 1 2 3467 Back O S of case to center of knockout 34 5 8 881 34 5 8 881 34 5 8 881 34 5 8 881 Length of electrical raceway 16 1 8 410 34 1 2 876 35 5 8 903 35...

Page 3: ...rature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 3 6 ft 1 8...

Page 4: ...46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30...

Page 5: ...rounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connec...

Page 6: ...tch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 5 BL R R BL BL 5 6 6 6 6 6 6 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 5 6 6 R R 6 Grayed compone...

Page 7: ...f is placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less...

Page 8: ...lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the one piece...

Reviews: