background image

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

C2-LE

Discharge Air (°F)

27

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/ft*

C2-LE

Parallel

1185

Conventional

1250

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

C2-LE

Frequency (hr)

6

Defrost Water (lb/ft/day)

6

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

C2-LE

Temp Term 

(

°

F

)

48

°

F

Failsafe (minutes)

30

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

C2-LE

CI/CO

**

17°F / 7°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***
4 ft 

1.3

6 ft 

1.8

8 ft 

2.3

12 ft 

3.3

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

3 of 8

P/N 0395955F

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

1

/

8

 

(155)

(Note*)

(Note*)

(Note*)

(Note*)

(Note:* Optional Accessory Items)

19 

(483)

3

/

4

 

(95)

12 

(305)

48 

(1219)

24 

3

/

8

 

(619)

18 

(406)

30 

1

/

2

 

(775)

FAN

L

3

/

8

 

(136)

27 

5

/

8

 

(703)

29 

1

/

4

 

(743)

30 

5

/

8

 

(778)

34 

5

/

8

 

(881)

38 

7

/

8

 

(986)

46 

1

/

2

 

(1182)

5

/

8

 

(219)

19 

(483)

C2-LE

14 

1

/

8

 

(359)

Dimensions shown as inches and (mm).

Multi-deck, 3 Display Levels

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Impact  

C2-LE

Dairy / Delicatessen 

Precut & Packaged Produce

Summary of Contents for C2-LE

Page 1: ...ion Thermostat Item Part Description Wiring Item HEATERS D Canopy Anti Sweat Heater 4 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS E Ballast Electronic 5 0376409 2 lamps 0376410...

Page 2: ...kout 38 1 4 972 64 3 8 1635 88 3 8 2245 136 1 2 3467 Back O S of case to center of knockout 34 5 8 881 34 5 8 881 34 5 8 881 34 5 8 881 Length of electrical raceway 16 1 8 410 34 1 2 876 35 5 8 903 35...

Page 3: ...rature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 3 6 ft 1 8...

Page 4: ...46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30...

Page 5: ...rounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connec...

Page 6: ...tch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 5 BL R R BL BL 5 6 6 6 6 6 6 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 5 6 6 R R 6 Grayed compone...

Page 7: ...f is placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less...

Page 8: ...lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the one piece...