Hussmann austral DO13-1 Series Installation Manual Download Page 3

PRODUCT INSTALLATION MANUAL

 

                         

                                                                              DO13 SELF SERVE OLIVE 

 

_________________________________________________________________________________________________________________________                                                                                                                                                                                                                                                      
Page 2

 

                                                                                                              Hussmann

 

Pre installation

 

 
Important Safety Instructions 

 
Please read the user manual carefully and store for later reference. In this document you will see these symbols with 
following meanings 

 

NOTE

 

Information in this manual is to be followed 
in conjunction with specifications, work 
practices and regulations of the customer, 
installing company and relevant industry.

 

 

 

CAUTION 

Care must be taken to avoid damage to 
drainage outlets and electrical equipment 
mounted under or at the rear of cases.

 

 

 

CAUTION

 

This symbol indicates electrical safety must 
be concerned

 

 

WARNING 

 
 

 

Leave enough space to install the system. The space requirement will be instructed in 

“Pre-installation” section. 

 

 

Before installing the system make sure the power source is accessible to the cases array. 

 

 

All the power source has to be properly earthed. 

 

 

If any potential fail or product disconformity is investigated, please consult a qualified service technician. 

 

 

Always disconnect the power of the cases before conducting any service or maintenance. 

 

 

Keep the case out of direct sunlight, fire hazardous environment, or high moisture or humidity area. 

 

 

Fail to install the system as instructed in this manual may void Hussmann Warranty. 

 

 REFRIGERANT WARNING 

 

 

Refrigerant is not factory charged. 

 

 

Default refrigerant is shown on the product rating plate.  
 

 

Other refrigerant types are available upon request  

 

 

Ensure  that  during  the  transportation  and  installation  the  refrigerant  circuit  is  not  damaged.  Please  contact 
Hussmann for product maintenance help. 
 

The installation should follow AS1677.2 or other local safety requirements.

 

Summary of Contents for austral DO13-1 Series

Page 1: ...O13 1 SERIES SELF SERVE OLIVE INSTALLATION MANUAL IM 015 Standard remote versions The following models are covered by this Manual DO13 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2...

Page 2: ...ling the waste drain 13 Connecting power supply 14 Installing sensor probes 15 Mounting fixtures 16 Commissioning 17 Cleaning case 17 Starting up 17 Start up checks 17 Decommissioning 17 Disposal 17 O...

Page 3: ...e system The space requirement will be instructed in Pre installation section Before installing the system make sure the power source is accessible to the cases array All the power source has to be pr...

Page 4: ...DO13 SELF SERVE OLIVE _________________________________________________________________________________________________________________________ Page 3 Hussmann Case Services Dimensions Fig 1 Service...

Page 5: ...and Transporting cases Case dimensions can be found in the product engineering data sheets This manual is a guide only Always refer to the latest case information available from Hussmann Customer Ser...

Page 6: ...e up no Case sequence no within line up Example 106076 42 4 identifies this case in the 4th sequence of the line 42 for the job 106076 As well as on the packaging the case identification number appear...

Page 7: ...sition the case allocated to this position first 3 Adjust the case height using the adjustable feet if fitted or metal shims do NOT use timber to ensure the case is level to within 1 5mm from front to...

Page 8: ...______________________________________________ Page 7 Hussmann Fig 6 Case Levelling Fig 7 Case twisting Make sure case is level Front to Back 1 5mm Side to Side 1 5mm Make sure all adjusting feet NOT...

Page 9: ...r leakage To seal the joins 1 Remove the shelves and racks from the end bays if necessary CAUTION Electrical cords are connected between Air Delivery Panels and Shelves on Meat and Deli cases Take car...

Page 10: ...refer to appendix 4 attaching case ends CAUTION Do not walk or sit on cases To join the cases 1 Draw up the required case tightly against the case already in position CAUTION Case joining bolts should...

Page 11: ...es and if required silicon seal to the floor once installation is complete and drains checked for water leaks Front Panel 1 Attached front panel and align with front skid rail refer figure 12 2 Push f...

Page 12: ...______________________________________________________ Page 11 Hussmann Side kickplate 1 Attached side kickplate as per drawing refer figure 14 2 Adjust slot in kickplate to suit Make sure kickplate i...

Page 13: ...an up stand The evaporator coils have been charged with dry nitrogen in the factory Fig 15 Refrigeration access holes CAUTION Do not run refrigeration lines from another compressor through a case Sinc...

Page 14: ...s to ensure they are free of leaks 8 Dehydrate the refrigeration system using the triple evacuation method Use a vacuum pump to 1000 microns for the first two evacuations and 500 microns on the third...

Page 15: ...to floor waste drains 3 Test for leakage by pouring water down the drain and ensure trap is primed before starting refrigeration 4 NOTE All joints to be glued with suitable adhesive Connecting Power...

Page 16: ...cases have the probes pre fitted at the factory Probe location as per Fig 17 CAUTION Refer to relevant State or Territory legislation relating to safe working heights Probe location 1 Air off probe i...

Page 17: ...__________________________ Page 16 Hussmann Mounting fixtures Replace racks and shelves etc as necessary to store requirements Fitting racks and shelves in manners other than configured as per the pro...

Page 18: ...ck that all fans and lights and light RCDs if installed are working correctly 3 Check the anti sweat circuit ensuring the thermostat is set correctly If installed 4 All electrical connections are secu...

Page 19: ...listed previously Disposal Case disposal is to be carried out by the following 1 Metal component removed and recycled 2 Remaining by commercial waste management Operation Loading Merchandise Cases sho...

Page 20: ...ny damaged electrical components are identified during inspection isolate case power and contact service contractor Visually inspect drain strainer and drain for any debris which could result in the d...

Page 21: ...with clean dry cloth 7 Remove the base trays wash with mild soapy water and rinse 8 Remove any foreign material from the base of the case 9 Remove all food scrap 10 Carefully flush the waste drain wi...

Page 22: ...cluding earth continuity and insulation resistance 10 Ensure that the correct fuse rating and type is fitted for all circuits 11 Clean the evaporator coil and check it for damage 12 Ensure that there...

Page 23: ...longer defrost duration A humid store may need more frequent defrost Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the origin...

Page 24: ...service P1 P2 P3 P4 P5 P6 Sensor break down value out of range or sensor incorrectly configured Check the sensors rating condition and replace if necessary HA Room temperature exceed the highest room...

Page 25: ...re when an end attaches to a single case and when it is common to two cases Ensure that correct and appropriate manual handling techniques are applied when fitting a patch end Cases must be sealed bef...

Page 26: ...r the remaining holes 6 Pull up the case ends lightly against the case 7 Adjust the case so that the end fits comfortably around the canopy and the top of the case and is level from front to back with...

Page 27: ...become pinched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or bec...

Page 28: ...pproval 45bar 652 psi Refrigerant temperature 40T70oC Room Temperature 30T70oC Phase Current 450mA Drive frequency 50Hz 150Hz Phase resistance 25 oC 36ohm 10 IP Rating IP65 Step angle 15o Linear advan...

Page 29: ..._____ Page 28 Hussmann Appendix 8 Warranty The information in this manual is for Qualified Persons Only It is NOT an Installation Guide for NON Qualified Persons To obtain warranty information or othe...