_________________________________________________________________________________________________________________________                                                                                                                                                                                                                                                      
Page 26

 

                                                                                                              Hussmann

 

Appendix 5 Risk analysis

 

 

HAZARD 

CONTROL MEASURES 

Electrical -   

                                                   

Replacement of electrical components

 

Request a service call. Electrically isolate cases before works 

Ergonomic -  

                                                             

Moving/ positioning/ adjusting cases

 

Staff must be trained in the correct procedures for setting up cases 

and ergonomic practices. PPE must be worn 

Falling -       

                                                       

Connecting sensor probe wiring during 
installation

 

Use of barriers & fall arrest systems as appropriate & in accordance 

with State & Territory Legislation. Safe working at heights 

Entanglement -      

                                                                         

Contact with fans when cleaning

 

Electrically isolate cases before work is carried out. Staff training, 

Cuts and stabbing -       

                                                       

Potential for cuts from broken fluorescent 
tube or during tube replacement

 

Electrically isolate cases. Staff not to replace tubes. Call service 

provider. PPE must be worn. 

Electrical -        

                                                               

Potential for electric shock when cleaning 
electrical fittings and components

 

Electrically isolate cases before work is carried out. Staff training, 

RCD. Keep electrical connections dry at all times. 

Falling -      

                                                                         

Climbing on shelves

 

Staff must be trained in OH&S procedures. MUST not climb on 

shelves or cases. 

Crushing -  

                                                          

Hands or fingers may become pinched or 
crushed during the positioning of base trays, 
shelves & stock

 

Staff must be trained in the correct procedures for setting up               

cases and ergonomic practices 

Slipping -    

                                                             

Drain may leak or become blocked causing 
water spillage

 

Visual Inspection and regular maintenance. Request service call 

when necessary.  

Cuts and stabbing -      

                                       

Potential for cuts caused by damaged or 
missing parts

 

Visual Inspection and regular maintenance. Request service call 

when necessary. PPE must be worn when handling broken or 

damaged parts. 

Ergonomic -  

                                                          

Stretching during the cleaning of the case 
and positioning of stock and shelves leading 
to strains and sprains

 

Staff must be trained in the correct procedures for cleaning cases & 

ergonomic practices. Cleaning tools which reduce the need for 

stretching should be used. 

Slipping -    

                                                             

Surfaces may become slippery due to 
spillage from  the case during operation or 
cleaning

 

Visual Inspection. Appropriate remedial action.  

Cuts and stabbing -      

                                       

Potential for cuts caused by sharp edges &  
evaporator coil during cleaning

 

PPE must be worn by staff 

Cuts and stabbing -     

                                     

Cleaning cold glass surfaces with hot water

 

Staff must be trained in the correct procedures for cleaning cases 

and ergonomic practices 

Crushing -     

                                                           

fingers, hands or body between doors

 

Operators to always open and close doors using handles provided, 

ensuring the area is clear of other persons. 

Electrical -      

                                                      

electrical connections in cases

 

Electrically isolate cases before work begins. Must be carried out by 

a service provider. Staff training. 

 

Table (3) Risk analysis

 

 

Summary of Contents for austral DO13-1 Series

Page 1: ...O13 1 SERIES SELF SERVE OLIVE INSTALLATION MANUAL IM 015 Standard remote versions The following models are covered by this Manual DO13 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2...

Page 2: ...ling the waste drain 13 Connecting power supply 14 Installing sensor probes 15 Mounting fixtures 16 Commissioning 17 Cleaning case 17 Starting up 17 Start up checks 17 Decommissioning 17 Disposal 17 O...

Page 3: ...e system The space requirement will be instructed in Pre installation section Before installing the system make sure the power source is accessible to the cases array All the power source has to be pr...

Page 4: ...DO13 SELF SERVE OLIVE _________________________________________________________________________________________________________________________ Page 3 Hussmann Case Services Dimensions Fig 1 Service...

Page 5: ...and Transporting cases Case dimensions can be found in the product engineering data sheets This manual is a guide only Always refer to the latest case information available from Hussmann Customer Ser...

Page 6: ...e up no Case sequence no within line up Example 106076 42 4 identifies this case in the 4th sequence of the line 42 for the job 106076 As well as on the packaging the case identification number appear...

Page 7: ...sition the case allocated to this position first 3 Adjust the case height using the adjustable feet if fitted or metal shims do NOT use timber to ensure the case is level to within 1 5mm from front to...

Page 8: ...______________________________________________ Page 7 Hussmann Fig 6 Case Levelling Fig 7 Case twisting Make sure case is level Front to Back 1 5mm Side to Side 1 5mm Make sure all adjusting feet NOT...

Page 9: ...r leakage To seal the joins 1 Remove the shelves and racks from the end bays if necessary CAUTION Electrical cords are connected between Air Delivery Panels and Shelves on Meat and Deli cases Take car...

Page 10: ...refer to appendix 4 attaching case ends CAUTION Do not walk or sit on cases To join the cases 1 Draw up the required case tightly against the case already in position CAUTION Case joining bolts should...

Page 11: ...es and if required silicon seal to the floor once installation is complete and drains checked for water leaks Front Panel 1 Attached front panel and align with front skid rail refer figure 12 2 Push f...

Page 12: ...______________________________________________________ Page 11 Hussmann Side kickplate 1 Attached side kickplate as per drawing refer figure 14 2 Adjust slot in kickplate to suit Make sure kickplate i...

Page 13: ...an up stand The evaporator coils have been charged with dry nitrogen in the factory Fig 15 Refrigeration access holes CAUTION Do not run refrigeration lines from another compressor through a case Sinc...

Page 14: ...s to ensure they are free of leaks 8 Dehydrate the refrigeration system using the triple evacuation method Use a vacuum pump to 1000 microns for the first two evacuations and 500 microns on the third...

Page 15: ...to floor waste drains 3 Test for leakage by pouring water down the drain and ensure trap is primed before starting refrigeration 4 NOTE All joints to be glued with suitable adhesive Connecting Power...

Page 16: ...cases have the probes pre fitted at the factory Probe location as per Fig 17 CAUTION Refer to relevant State or Territory legislation relating to safe working heights Probe location 1 Air off probe i...

Page 17: ...__________________________ Page 16 Hussmann Mounting fixtures Replace racks and shelves etc as necessary to store requirements Fitting racks and shelves in manners other than configured as per the pro...

Page 18: ...ck that all fans and lights and light RCDs if installed are working correctly 3 Check the anti sweat circuit ensuring the thermostat is set correctly If installed 4 All electrical connections are secu...

Page 19: ...listed previously Disposal Case disposal is to be carried out by the following 1 Metal component removed and recycled 2 Remaining by commercial waste management Operation Loading Merchandise Cases sho...

Page 20: ...ny damaged electrical components are identified during inspection isolate case power and contact service contractor Visually inspect drain strainer and drain for any debris which could result in the d...

Page 21: ...with clean dry cloth 7 Remove the base trays wash with mild soapy water and rinse 8 Remove any foreign material from the base of the case 9 Remove all food scrap 10 Carefully flush the waste drain wi...

Page 22: ...cluding earth continuity and insulation resistance 10 Ensure that the correct fuse rating and type is fitted for all circuits 11 Clean the evaporator coil and check it for damage 12 Ensure that there...

Page 23: ...longer defrost duration A humid store may need more frequent defrost Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the origin...

Page 24: ...service P1 P2 P3 P4 P5 P6 Sensor break down value out of range or sensor incorrectly configured Check the sensors rating condition and replace if necessary HA Room temperature exceed the highest room...

Page 25: ...re when an end attaches to a single case and when it is common to two cases Ensure that correct and appropriate manual handling techniques are applied when fitting a patch end Cases must be sealed bef...

Page 26: ...r the remaining holes 6 Pull up the case ends lightly against the case 7 Adjust the case so that the end fits comfortably around the canopy and the top of the case and is level from front to back with...

Page 27: ...become pinched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or bec...

Page 28: ...pproval 45bar 652 psi Refrigerant temperature 40T70oC Room Temperature 30T70oC Phase Current 450mA Drive frequency 50Hz 150Hz Phase resistance 25 oC 36ohm 10 IP Rating IP65 Step angle 15o Linear advan...

Page 29: ..._____ Page 28 Hussmann Appendix 8 Warranty The information in this manual is for Qualified Persons Only It is NOT an Installation Guide for NON Qualified Persons To obtain warranty information or othe...

Reviews: