All Hussmann Cases have been factory tested to AS1731, 25
C at 60% RH. For best performance, store temperature
should be maintained at or below 24
C at 50% RH, otherwise
an “air ventilation kit” may be required to avoid under or rear
cabinet sweating.
To avoid condensation build-up, cases should be positioned to allow air to freely circulate around the underside and rear
of the case. Ideally, the floor will be levelled.
Cases must not be positioned in areas that may be subject to heat or air currents such as ventilation ducts, open doors or
windows, direct sunlight, electric fans or ovens, etc. Otherwise the cabinet may show poor temperature performance or the
operating life is affected.
NOTE
Refer to product MSDS for all hazardous substances used
during installation in relation to their application, PPE, first aid,
disposal and emergency management. Refer page 27 (Risk
Analysis)
For MSDS sheet contact your Hussmann Representative
Handling and Transporting cases
MANDATORY USE OF STRAP AND EDGE PROTECTORS FOR THE
TRANSPORTATION OF HUSSMANN REFRIGERATED CASE
Hussmann Refrigerated Display Cases are to be secured correctly during transport to ensure damage
free arrival at their destination. It is the responsibility of the Transport Company to ensure that the
correct method of loading and securing Refrigerated Display cases is used.
Refrigerated cases are to be strapped using the following method:-
•
A heavy duty strap protector and the correct rated strapping are to be used to tie down cases.
•
The cases are to be tied down as indicated on the exterior of the case wrapping.
“
STRAP HERE”
See figure 2a and figure 2b
.
•
Cases should not be transported without the use of the heavy duty strap protector otherwise
damage to the exterior case panels will occur.
•
Hussmann Storage Warehouse Managers will refuse to load cases onto transport and trucks
will be turned away if the heavy duty protector and the correct rated strapping are not used.