Rev. 0506 

11

Electrical

WIRING COLOR CODE

GREEN

GROUND

PURPLE

ANTI-SWEAT

ORANGE

LIGHTS

YELLOW

RECEPTACLE

RED / BLACK 

T-STAT /SOLENOID230V

BLACK / WHITE

T-STAT / SOLENOID 115V

BROWN

FAN MOTORS

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual configura-

tion as checked in the “TYPE INSTALLED” boxes. 

Electrical Circuit Identification

Standard  lighting  for  all  models  will  be  full  length 

fluorescent  lamps  located  within  the  case  at  the 

top.

The switch controlling the lights, the plug provided for 

digital scale, and the thermometer are located at the 

rear of the case mullion. 

ELECTRICAL SERVICE RECEPTACLES  

(When Applicable)

The  receptacles  located  on  the  exterior  of  the 

merchandiser  are  intended  for  scales  and  lighted 

displays. They are not intended nor suitable for large 

motors or other external appliances

.

FIELD WIRING & SERIAL PLATE 
AMPERAGE

Field Wiring must be sized for component amperes 

printed on the serial plate. Actual ampere draw may be 

less than specified. Field wiring from the refrigeration 

control  panel  to  the  merchandisers  is  required  for 

refrigeration thermostats. Most component amperes 

are  listed  in  the  “Case  Specs”  section,  but  always 

check the serial plate.

BALLAST LOCATION

Ballasts are located on the right rear panel. 

WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes 

stamped on the serial plate.  Actual ampere draw may 

be less than specified. Field wiring from the refrigera-

tion control panel to the merchandisers is required for 

refrigeration thermostats.  Most component amperes 

are  listed  in  the  “Case  Specs”  section,  but  always 

check the serial plate.

ASHRAE COLOR CODE

NOTE:  All other manufacturers; no known sensor codes

Case Control Systems

SENSOR

COLORS

Manufacturer ® >

EIL

CPC

Location
Coil Inlet

Color

Blue

Blue

Part#

225-01-1755

225-01-3255

Coil Outlet

Color

Red

Red

Part#

225-01-1757

225-01-3123

Discharge Air

Color

Green

Green

Part#

225-01-1756

225-01-3260

Return Air

Color

Purple

Green

Part#

225-01-1758

225-01-3260

Defrost Term.

Color

White

Orange

Part#

225-01-0650

225-01-3254

Liquid Line

Color

White

Blue

Part#

225-01-0650

225-01-3255

Summary of Contents for ASC-LG

Page 1: ...ASC LG ASCS LG Rev 0506 Installation Operation Manual ASC LG ASCS LG Lift up Curved Glass Refrigerated Service Gelato and Ice Cream Case INSTALLATION OPERATION GUIDE ASC LG ASCS LG 0506...

Page 2: ...CHINO PRODUCT CONTROL The serial number and shipping date of all equipment has been recorded in Hussmann s files for warranty and replacement part purposes All correspondence pertaining to warranty o...

Page 3: ...ow be lifted off the crate skid Lift only at base of stand EXTERIOR LOADING These models have not been structurally designed to support excessive external loading Do not walk on their tops This could...

Page 4: ...sed under leg or by use of 2x6 or 2x4 leg brace Remove side and back leg braces after case is set 3 Set second case as close as possible to the first case and level case to the first using the instruc...

Page 5: ...l should be insulated to prevent condensation DIPPER WELL An optional NSF approved dipper well may be installed on the back of case The exact location of the dipper well will be determined by the cust...

Page 6: ...on valves will be installed on the coil inlet coil outlet and in the discharge air Some supermarkets require a 4th sensor in the return air Case controllers will be located in the electrical race way...

Page 7: ...Rev 0506 Paragon ERC 2 Programming Settings Instructions...

Page 8: ...ASC LG ASCS LG 0506 Paragon ERC 2 Programming Settings Instructions Cont d...

Page 9: ...Rev 0506 Paragon ERC 2 Programming Settings Instructions Cont d...

Page 10: ...ASC LG ASCS LG 0506 10 Paragon ERC 2 Programming Settings Instructions Cont d...

Page 11: ...pere draw may be less than specified Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats Most component amperes are listed in the Case Spec...

Page 12: ...void the use of supplemental flood or spot lighting Display light intensity has been designed for maximum visibility and product life at the factory The use of higher output fluorescent lamps H O and...

Page 13: ...ss from improper caustic solutions is irreparable In addition to cleaning the glass with the recommended product there are precautions that should be taken when working and cleaning the inside of the...

Page 14: ...cking case will affect its proper operation Make sure that the product is not higher then the discharge air of the case and does not block the center return air grill 6 Make sure all front glass is pr...

Page 15: ...TRUCTIONS In order to replace or adjust the glass the glass must be placed in the raised position The underside of the clamp is exposed revealing the tightening screws By turning these screws counterc...

Page 16: ...5 120 5 Forced 41 2 4 16 1 0 72 1 04 3 05 15 0 3 13 Air Axial 208V ASC LG ASCS LG Ice Cream Electric Defrost Option 4 450 1 800 30 10 20 150 20 Forced 41 2 1 30 2 0 18 0 35 1 83 15 65 15 0 1 04 Air Ax...

Page 17: ...SENSOR ELECT T STAT 225 01 3355A NC C NO 240V COM 120V _ SENSOR DELAY RELAY 208 VOLT COIL MARS 90342 25 01 1342 4 REFRIGERATION 3 DEFROST L2 L1 G AIR SWEEP WARMER WIRE 125 01 3032 180w 115V L WARMER...

Page 18: ...RS 6 450W 115VAC BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L L LIGHT SWITCH BACK COIL FRONT COIL NC C NO 240V COM 120V _ SENSOR SENSO...

Page 19: ...G FAN DELAY LIMIT SWITCH 225 01 2046 REAR CHANNEL 125 01 0767 10W FT 115V 8 FT EVAPORATOR FAN 2 GE 9W 115V 00001212 M M DEFROST HEATER LIMIT SWITCH 600 22 0050 DRAIN HEATER 1 240W 208 V 125 02 1104 DE...

Page 20: ...SPX30 2 F25T8 SPX30 1 F32T8 SPX30 LIGHT SWITCH DRAIN HEATER 1 300W 208 V DEFROST HEATERS 6 750W 208VAC BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FU...

Page 21: ...BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L CAP CANOPY LIGHTS 6 F32T8 SPX30 NOSE LIGHTS 3 F32T8 SPX30 LIGHT SWITCH BUNDLE COLOR ORANG...

Page 22: ...2912T 230VAC DISPLAY UNIT DEFROST TIMER 230V 50 60 Hz 125 01 2301 AIR TEMP DEFROST TEMP 125 01 2301A MAX 16 FEET N GROUND FAN COMP 1 DEFROST W G BK L AIR SWEEP HEATER W 120 VAC 125 01 ANTI SWEAT SWITC...

Page 23: ...LAY UNKIT OMNI STAT 230V 50 60 Hz 952912T 125 01 2301 AIR TEMP DEFROST TEMP 125 01 2301A MAX 16 FEET N GROUND FAN COMP 1 DEFROST W G BK L AIR SWEEP HEATER W 120 VAC 125 01 ANTI SWEAT SWITCH 125 01 031...

Page 24: ...EATER W 120 125 01 ANTI SWEAT SWITCH 125 01 0311 DUPLEX RECEPTACLE LEVITON 5320 W 125 01 0096 AIR SWEEP FAN MOTORS 2 125 01 3142 A M M RJ 45 NETWORK JACK 125 01 0200 125 01 0203 125 01 0204 PUMP DOWN...

Page 25: ...25 01 0096 AIR SWEEP FAN MOTORS 2 125 01 3142 A M M RJ 45 NETWORK JACK 125 01 0200 125 01 0203 125 01 0204 PUMP DOWN SOLENOID 225 01 3206 NC L PUMP DOWN SWITCH 125 01 0311 L DRAIN HEATER RELAY COIL 20...

Page 26: ...RECEPTACLE LEVITON 5320 W 125 01 0096 AIR SWEEP FAN MOTORS 2 125 01 3142 A M M RJ 45 NETWORK JACK 125 01 0200 125 01 0203 125 01 0204 PUMP DOWN SOLENOID 225 01 3206 NC L PUMP DOWN SWITCH 125 01 0311 L...

Page 27: ...20 L CANOPY LIGHTS 2 F32T8 SPX30 NOSE LIGHTS 1 F32T8 SPX30 LIGHT SWITCH POWER REQUIRED 115 VAC 50 60 Hz 1 3 WIRE BALLAST 125 01 3266 FULHAM LH3 120 L CAP CAP ELECT T STAT 225 01 3355A SENSOR NC C NO 2...

Page 28: ...25T8 SPX30 LIGHT SWITCH POWER REQUIRED 115 VAC 50 60 Hz 1 3 WIRE BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L ELECT T STAT 225 01 3355...

Page 29: ...01 3266 FULHAM LH3 120 L CANOPY LIGHTS 4 F32T8 SPX30 NOSE LIGHTS 2 F32T8 SPX30 LIGHT SWITCH POWER REQUIRED 115 VAC 50 60 Hz 1 3 WIRE BALLAST 125 01 3266 FULHAM LH3 120 L ELECT T STAT 225 01 3355A SEN...

Page 30: ...F32T8 SPX30 NOSE LIGHTS 2 F25T8 SPX30 1 F32T8 SPX30 LIGHT SWITCH POWER REQUIRED 115 VAC 50 60 Hz 1 3 WIRE BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266...

Page 31: ...M LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L CAP CANOPY LIGHTS 6 F32T8 SPX30 NOSE LIGHTS 3 F32T8 SPX30 LIGHT SWITCH DRAIN...

Page 32: ...T DEFROST TIMER DISPLAY UNIT 115V 60 Hz 125 01 2304 AIR TEMP DEFROST TEMP 125 01 2301A MAX 16 FEET N GROUND FAN COMP 1 DEFROST PUMP DOWN SOLENOID 225 01 3206 NC L PUMP DOWN SWITCH 125 01 0311 L BALLAS...

Page 33: ...aller is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system 1 4 The installer should perform a complete s...

Page 34: ...for the following 1 Has the refrigerator been loaded with warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocke...

Page 35: ...during periods of inactivity f Minimize the transfer time of perishables from storage to display g Keep meat under refrigeration in meat cut ting and processing area except for the few moments it is b...

Page 36: ...for your particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Additional copies of this publication may be obtained by...

Reviews: