E.18
TE 250 - 310 2012 I.E. / TE 250 - 310 2012 I.E. USA
TC 250 2012 - TC 250 2012 I.E. USA
TXC 250 - 310 2012 I.E. USA
H10021
1
2
H11106
4
3
GENERAL PROCEDURES
Workshop Manual Ed. 12-2011
Start-up relay removal (TE-TXC)
- Remove saddle and left-hand side panel (in this order) as outlined in the
relevant paragraphs.
- Disconnect the negative and positive cables of the battery.
- Disconnect the starter motor positive cable (1) from the solenoid starter.
- Disconnect the connector (2) and remove the solenoid starter (3) from its
mount.
Condenser (TC)
This operation must be performed with a cool engine.
- Cut the clamp (1) and disconnect the connector (2).
- Pull outwards the condenser (3) so that it comes out of the supporting bracket
(4).