Maintenance
Before each
use
Daily
Weekly
When suc-
tion is low
6 months or
1000h
12 months or
2000h
Look for signs of wear,
damage or loose con-
nections of the controls
before the unit is con-
nected.
X
Do a check that the
Longopac is correct.
X
Do a check of the filter
cleaning mechanism.
X
Do a check of the
wheels. Look for dam-
age and bad connec-
tions.
X
Clean the pre-filter.
X
Replace the pre-filter.
X
X
Replace the Hepa filter
X
X
To clean the dust extractor
It is important to clean the dust extractor to prevent
circulation of dangerous dust. Always clean the dust
extractor before it is moved from the work area.
WARNING: Turn the motor switch to its OFF
position and disconnect the cord from the
wall outlet before you clean or do
maintenance to the product.
• All equipment once used must be regarded as
contaminated and be treated thereafter.
• All parts that are contaminated after service work
must be disposed in a correct procedure in plastic
bags. Refer to local regulations.
• Use correct personal equipment when you clean the
product. Refer to
Personal protective equipment on
page 7
.
• Clean the external surface with a moist cloth.
• Clean the filters and the dust extractor in applicable
area.
• Vacuum the pre-filter from the inside. Always use
dust extractors with Hepa filter and a soft brush to
not damage the filter.
• Do not use water on electrical components.
• Do not clean the dust extractor with high pressure
(air or water).
• Do not put tools on the surface of the filter, it can
cause damage to the filter.
• Do not make a hole in the Hepa filter, it can cause a
health risk.
Filter change
WARNING: Use personal safety equipment,
refer to
Personal protective equipment on
page 7
, during filter change. Dust can come
out during filter change.
WARNING: Always turn the motor switch in
the Off position and disconnect the cord
from the wall outlet during filter change.
To clean the pre filter
The filter must be cleaned from time to time. This must
be done before changing the plastic bag collection
system and should also be done when work is
completed or when there is poor suction..
CAUTION: Avoid hitting or dragging items
across the filter surface as this will damage
the filter.
CAUTION: Do not use water to clean the
filters.
1. While running the dust extractor, seal the inlet using
the inlet plug or the inlet valve.
2. Let the dust extractor build up vacuum for 5
seconds, then quickly push and hold down the Jet
Pulse handle for 5 seconds.
3. Repeat step 2 five times. It is important to let the
dust extractor rebuild the vacuum in between every
repetition.
10
877 - 003 -
Summary of Contents for T 8600
Page 46: ...46 877 003 ...