
English – 15
4.2.5 Gun is activated
Gun is open - Control piston is closed. Micro switch is deactivated.
Motor starts.
Pump
3 BAR
Inlet
Non return valve
Outlet
3 BAR
3 BAR
4.2.6 Machine run
Machine runs (normal working pressure). Gun is open.
Pump
100 BAR
Inlet
Non return valve
Outlet
98 BAR
3 BAR
Appendices and schedules