CAUTION: The power supply from the
product or generator must be sufficient and
constant to make sure that the motor
operates without problems. Incorrect voltage
causes the power consumption and the
temperature of the motor to increase until
the safety circuit releases. The dimension of
the power cord must agree with national and
local regulations. The dimension of the
mains socket must agree with the amperage
for the electrical socket and extension cable
of the product.
If the power mains has higher system
resistance, short voltage drop can occur
when the product is started. This can
influence the operation of other products, for
example flicker on the lights.
• Make sure that the power, fuse and mains voltage
are the same as the voltage shown on the rating
plate of the product.
• Always stop the product before you disconnect the
power plug.
• Do not use the product if the power cord or power
plug is damaged. Hand it in to an approved service
center for repair. A damaged power cord can cause
serious injury and death.
• Use the power cord correctly. Do not use the power
cord to move, pull or disconnect the product. Pull the
power plug to disconnect the power cord. Do not pull
the power cord.
• Do not operate the product in water depths where
the equipment of the product gets wet. The
equipment can become damaged and the product
can become live and cause injury.
• Do not get more moisture into the product than the
water supplied by the water system. Keep the
product away from rain. Water that goes into the
product increases the risk of electrical shock.
• Always disconnect the power cord before you
connect or disconnect the connection for the motor
cable and the electrical enclosure.
Guide values for power source
Nominal
voltage
from power
source, V
Min. voltage at
the product, V
Max. voltage at
the product, V
Frequency,
Hz
Nominal
current, A
Motor out-
put
Min. cable
area
mm2/AWG
Max. cable
length m/ft
3x220
200
240
50/60
50
11+1.5
10/7
190/620
3x400/440/
480
380
480
50/60
30
11+1.5
6/9
190/620
3x220
200
240
50/60
50
11+1.5
10/7
190/620
3x400/440/
480
380
480
50/60
30
15+1.5
6/9
190/620
Grounded product instructions
WARNING: Incorrect connection can result
in electrical shock. Speak to an approved
electrician if you are not sure if the product
is correctly grounded.
Do not do modifications to the power plug
from its factory specification. If the power
plug is not correct for the mains outlet, let an
approved electrician install a correct mains
outlet. Obey local regulations and laws.
If you do not fully understand the
instructions about the grounded product,
speak to an approved electrician.
The product has a grounded power cord and power
plug. Always connect the product to a grounded mains
outlet. This decreases the risk of electrical shock if there
is a malfunction.
Do not use electrical adapters with the product.
Extension cables
• Use only approved extension cables with sufficient
length.
• The rated value on the extension cable must be the
same or higher than given on the rating plate of the
product.
• Use grounded extension cables.
• When you operate the product outdoors, use an
extension cable that is applicable for outdoor
operation. This decreases the risk of electrical
shock.
• Keep the connection to the extension cable dry and
off the ground.
• Keep the extension cable away from heat, oil, sharp
edges or moving parts. A damaged cable increases
the risk of electrical shock.
• Make sure that the extension cable is in good
condition and not damaged.