![Husqvarna K770 SmartGuard Workshop Manual Download Page 69](http://html.mh-extra.com/html/husqvarna/k770-smartguard/k770-smartguard_workshop-manual_171400069.webp)
The blue plug above the stop button closes the circuit to
OilGuard (E in the illustration above). To override the
OilGuard function, remove the blue plug (A) with a
screwdriver and replace it with an orange plastic plug
(B).
A
B
6.17.2 To examine the power supply for the
OilGuard
1. Remove the filter and cylinder cover.
2. Connect a multimeter to a ground point and the point
of measure. Measure at idle rpm. The voltage must
be 20–40 V AC.
1453 - 001 - 02.04.2020
Repair and servicing - 69