English – 17
OPERATING
Gradual start and overload protection
The machine is equipped with electronically controlled gradual start and overload protection.
* If the system has shut down due to overheating, the lamps will continue flashing until the system has cooled down and
is ready to be restarted.
The electronics cut the current immediately if the blade jams.
Managing dust
Water cooling must always be used. Dry cutting causes immediate overheating and machine and cutting blade failure
with a risk of personal injury.
Adjust water flow using the tap to bind the cutting dust. The volume of water required varies depending on the type of
job at hand.
If water hoses loosen from their supply sources, this indicates that the machine is connected to a water pressure that is
too high. See instructions under the "Technical data" heading for recommended water pressure.
Indication on the machine
Cause
Possible action
1 green lamp:
Indicates the tool is connected to the
power unit and is ready for use.
Power output is less than 70% of the
maximum available output when in use.
2 green lamps:
Power output is between 70% and 90% of
the maximum available output when in
use.
3 green lamps:
Optimum cutting speed.
Power output is more than 90% of the
maximum available output.
3 green lamps and 1 yellow:
Tool under load so power output drops.
Reduce the load to attain optimum
cutting speed.
3 green lamps, 1 yellow: and 1
red:
The system is becoming overheated.
Reduce the load or increase motor and
power unit cooling.
All lamps on or flashing:
The system is overheated and can stop
at any time.*
Reduce the load or increase motor and
power unit cooling.
Power reduction:
Motor cooling can be improved by
increasing the amount of coolant or using
colder water.
Automatic reduction in maximum
available output. Power reduction
attempts to avoid overheating and
automatic shut-down of the system.
Power unit cooling can be improved by
changing air filter or by placing the power
unit in a location with cooler ambient
temperature.
Summary of Contents for K 6500 II Ring
Page 30: ...30 English WIRING DIAGRAM Wiring diagram ...
Page 60: ...60 Spanish ESQUEMA DE CONEXIONES ELÉCRICAS Esquema de conexiones eléctricas ...
Page 90: ...90 Portuguese ESQUEMA ELÉCTRICO Esquema eléctrico ...
Page 120: ...120 Greek à π ø πø ÈÔ Î Ïˆ ˆÛË ...
Page 121: ......
Page 122: ......
Page 123: ......