4. Attach the Longopac holder to the rear part of the
container (A). Then attach the Longopac holder to
the sides and to the front of the container (B). Push
the Longopac holder up until you hear a solid click.
(Fig. 19)
5. Make sure that the Longopac is sealed. (Fig. 20)
6. Pull the outer layer of the Longopac cassette down.
(Fig. 21)
7. Close the bottom of the Longopac with a cable tie.
(Fig. 22)
To discard a full Longopac bag and
prepare a new Longopac bag
WARNING:
Lift the Longopac bag with
caution, a full Longopac bag can be heavy.
Make sure that the cable ties are closed
correctly before you lift the Longopac bag.
1. Pull out the Longopac bag (A) and attach a cable tie
(B) to close the new Longopac bag. (Fig. 23)
2. Shake down the dust in the used Longopac bag.
3. Attach a cable tie 10 cm/3.9 in. below the first cable
tie to close the used Longopac bag. Cut off the
Longopac bag between the cable ties. (Fig. 24)
4. If the remaining part of the Longopac bag cassette
is too small to prepare a new Longopac bag, install
a new Longopac bag cassette. Refer to
new Longopac bag cassette on page 15
.
5. Obey local regulations for disposal of the full
Longopac bag.
To do after completed work
1. Do the filter purge procedure. Refer to
dust particles from the prefilter during operation on
page 15
.
2. Stop the product, refer to
on page 15
or
To start and stop DE 110/DE 120 on
page 15
.
3. Discard the Longopac bag. Refer to
Longopac bag and prepare a new Longopac bag on
page 16
.
4. Clean the product. Refer to
page 17
.
5. Prepare the product for transportation. Refer to
move the product long distances on page 21
.
Maintenance
Introduction
WARNING:
Product related accidents
occur during the troubleshooting, servicing
and maintenance as the operator must be
in the risk area of the product. The operator
must be careful, make a plan and prepare
the work to prevent accidents.
WARNING:
Before you do
maintenance, make sure that the motor
switch and the pump switch are in the Off
positions. Disconnect the power cord and
remove the pump cable.
WARNING:
Only let an approved
electrician do all checks of the electric
components.
WARNING:
Make sure that you do
not make a hole in the filter. Risk of dust
dispersion.
WARNING:
Make sure that you
obey all local regulations to dispose the
dangerous dust correctly, before and during
maintenance.
Maintenance schedule
The maintenance intervals are calculated from daily use
of the product. The intervals change if the product is not
used daily.
Maintenance
Before
each use
Daily
Weekly
When
suction is
low
Each 6
months or
600 h
Each 12
months or
2000 h
Do the filter purge procedure. Refer to
To remove dust particles from the prefil-
ter during operation on page 15
.
X
16
1587 - 007 - 24.01.2022
Summary of Contents for DE 110
Page 3: ...4 5 A 6 7 A 8 9 10 1 6 2 3 4 7 8 5 11 ...
Page 4: ...38 11 2 42 12 3 51 2 63 21 2 76 3 12 13 14 15 16 X 3 5 17 A B 18 A B 19 ...
Page 5: ...20 21 22 A B 23 24 A B 25 26 27 ...
Page 6: ...28 A B C 29 30 31 32 33 34 35 ...
Page 7: ...36 ...
Page 93: ...1587 007 24 01 2022 93 ...
Page 94: ...94 1587 007 24 01 2022 ...
Page 95: ...1587 007 24 01 2022 95 ...