DE 110
DE 120
1 ½ (38)
48 (82)
2 (51)
87 (147)
1 ⅔ (42)
59 (100)
2 1/2 (63)
132 (224)
2 (51)
87 (147)
3 (76)
192 (327)
Note:
If the airflow is less than 20 m/s (66 ft/s), the
sound alarm and the warning symbol comes on. Refer to
Warnings on the control panel (DE 110/DE120) on page
20
.
To select the hose nozzle diameter
Note:
If you do not select the correct hose diameter,
the airflow warning system will come on.
When you start the product, the last selected hose
diameter is automatically selected.
• Push the button to select the correct hose diameter.
The green LED tells which diameter you have
selected. (Fig. 12)
To start and stop DE 110S
Note:
Wait for 5 seconds after you start the product
to operate with full suction. The suction is not at full
capacity directly at start.
1. Make sure that the frequency and voltage shown on
the rating plate agree with the power supply.
2. Make sure that the On/Off switch is set to the "0"
position.
3. Connect the product to an applicable power socket.
4. Push the On/Off switch. (Fig. 13)
a) Push "I" to start the product.
b) Push "II" for automatic start. Refer to
start function (Only 230V DE 110S and DE 110)
on page 14
.
5. To stop the product, set the On/Off switch to "0".
6. Disconnect the product from the power socket.
To start and stop DE 110/DE 120
Note:
Wait for 5 seconds after you start the product
to operate with full suction. The suction is not at full
capacity directly at start.
1. Make sure that the frequency and voltage shown on
the rating plate agree with the power supply.
2. Connect the product to an applicable power socket.
3. Push the "I" on the main switch to start the product.
(Fig. 14)
4. Push the On/Off button to start and stop the
operation. (Fig. 15)
a) Push "I" to start the operation.
b) Push "A" for automatic operation start. Refer to
Automatic start function (Only 230V DE 110S
.
5. To stop the operation, push the On/Off button. The
button goes off when you stop the operation.
6. Push the "0" on the main switch to stop the product.
7. Disconnect the product from the power socket.
Hour meter (DE 110/DE120)
The hour meter shows the total operation time of the
product in hours.
To remove dust particles from the
prefilter during operation
The filter purge procedure cleans the prefilter from
unwanted material. Do the procedure in these situations:
• Before a work stop or at the end of each work day.
If the product is off for a while, it gives the dust
more time to fall down. This makes the filter purge
procedure more powerful.
• When the suction is not sufficient.
• Before installation of a new Longopac bag.
• When the prefilter clogged alarm goes off. Refer to
the instructions on the decal on the prefilter cover.
1. Start the product. Refer to
110S on page 15
or
120 on page 15
.
2. Close the air flow that moves through the air intake
with the air intake plug or the intake valve to make
vacuum. (Fig. 16)
3. Wait 5 seconds until vacuum is made, then push the
filter purge button. Do this step 3 to 5 times. It is
important to let the product make vacuum between
each button push. (Fig. 17)
If the suction is not sufficient after this procedure, it is
necessary to clean the prefilter with water. Refer to
clean the prefilter with water on page 18
.
To install a new Longopac bag cassette
CAUTION:
Clean the prefilter before
you install a new Longopac cassette. Refer
to
To remove dust particles from the prefilter
.
1. Put the Longopac cassette around the inner edge of
the Longopac holder.
2. Remove the 4 straps after you put the Longopac in
the holder.
3. Pull the inner layer of the Longopac cassette up (A)
and fold it into the holder (B). (Fig. 18)
1587 - 007 - 24.01.2022
15
Summary of Contents for DE 110
Page 3: ...4 5 A 6 7 A 8 9 10 1 6 2 3 4 7 8 5 11 ...
Page 4: ...38 11 2 42 12 3 51 2 63 21 2 76 3 12 13 14 15 16 X 3 5 17 A B 18 A B 19 ...
Page 5: ...20 21 22 A B 23 24 A B 25 26 27 ...
Page 6: ...28 A B C 29 30 31 32 33 34 35 ...
Page 7: ...36 ...
Page 93: ...1587 007 24 01 2022 93 ...
Page 94: ...94 1587 007 24 01 2022 ...
Page 95: ...1587 007 24 01 2022 95 ...