Check
Possible cause
Procedure
Spark plug.
The spark plug is dirty or wet.
Make sure that the spark plug is dry and
clean.
The spark plug electrode gap is incorrect.
Clean the spark plug. Make sure that the
electrode gap is correct. Make sure that the
spark plug has a supressor.
Refer to technical data for correct electrode
gap.
The spark plug is loose.
Tighten the spark plug.
The engine starts but stops again
Check
Possible cause
Procedure
Fuel tank.
Incorrect fuel type.
Empty the fuel tank and fill it with cor-
rect fuel.
Air filter.
The air filter is clogged.
Clean the air filter.
Transportation and storage
Transportation and storage
• Always allow the product to cool down before
storage.
• For storage and transportation of the product and
fuel, make sure that there are no leaks or fumes.
Sparks or open flames, for example from electrical
devices or boilers, can start a fire.
• Always use approved containers for storage and
transportation of fuel.
• Empty the fuel before transportation or before long-
term storage. Discard the fuel at an applicable
disposal location.
• Attach the transport guard during transportation and
storage.
• Remove the spark plug cap from the spark plug.
• Attach the product during transportation. Make sure
that it cannot move.
• Clean and do servicing on the product before long-
term storage.
Technical data
324L
Engine
Cylinder displacement, cu.in/cm
3
1.53/25
Idle speed, rpm
3100
Recommended max. speed, rpm
12000
Maximum engine power acc. to ISO 8893, kW/hp @ rpm
0.7/7000
Catalytic converter muffler
No
1323 - 002 - 08.07.2020