66
– English
ELECTRICAL SYSTEM
Checking the generator
Connect the ohm meter to the cylinder
(point A1) and point B. The ohm meter
should read 0.9-1.3 ohm.
Replace a generator that has higher or
lower values.
Connect the ohm meter to points B and C.
The ohm meter should read 3-4 ohm.
Replace the handle loop that has a higher
value.
Connect the ohm meter to points C and D.
The ohm meter should read 0.7-2.5 ohm.
Replace a heat loops that has higher
values.
Check the handle loop
Checking the heat loops in the rear handles
A1
B
B
C
Connect the ohm meter across the switch.
The ohm meter should read more than
1000 ohm with the switch in position "0".
The ohm meter should read, at the highest,
0.1 ohm with the switch in position "1".
Checking the power switch
D
C
Eng, p 40-82
96-09-13, 10.25
66
Summary of Contents for 268K, 272K
Page 1: ...101 88 55 26 Workshop Manual Husqvarna Chain Saws ...
Page 21: ...English 21 SERVICE DATA 15 4 6 4 3 28 4 ...
Page 23: ...English 23 SERVICE DATA 20 4 2 4 28 2 9 3 2 9 6 2 2 13 ...
Page 25: ...English 25 SERVICE DATA 3 4 2 3 2 3 25 30 2 3 2 3 2 3 2 3 8 10 2 3 2 3 3 4 20 2 3 ...
Page 27: ...English 27 SERVICE DATA 15 25 12 14 8 10 3 4 3 4 3 4 3 5 3 4 3 4 1 2 ...
Page 29: ...English 29 254 SERVICE DATA 5 3 2 28 4 10 20 4 13 4 9 3 5 ...
Page 31: ...English 31 SERVICE DATA 2 2 28 4 9 20 4 5 13 4 4 5 3 9 5 ...
Page 33: ...English 33 272 268 272 61 SERVICE DATA 3 4 28 4 10 15 4 3 3 5 14 6 4 6 1 1 3 1 3 9 3 ...
Page 35: ...English 35 SERVICE DATA 6 4 35 11 20 7 7 3 17 3 4 7 7 6 4 3 1 9 ...
Page 37: ...English 37 SERVICE DATA 30 40 10 12 5 6 6 2 3 4 5 3 5 3 5 5 6 20 22 5 12 14 ...
Page 39: ...English 39 SERVICE DATA 5 4 40 12 20 4 12 17 10 8 9 4 6 5 5 7 3 3 ...