  Compression

  MAINTENANCE AND INSPECTION

1.  Daily maintenance is required to ensure that the tool is kept in good working condition.
2.  Do not store the tool in a humid environment.
3.  Wipe away any excess oil with a soapy cloth.
4.  Provided that maintenance of the tool is carried out regularly, the tool should provide  

 

many years of service.

5.  Should you experience any difficulty with the operation and maintenance of this tool,  

 

contact Huskie’s technical support department at 1-800-860-6170.

1.  Select the appropriate compression die set for the connector and cable being used. 
2.   To insert the dies, depress the die release pin on the ram, and slide die into place. 

Then, depress release pin on “C” head as well and slide other die half in place. Be sure 
both die halves are secure before operating the tool.

3.  Position the connector between the dies and pump tool handle until the connector is 

held in place. Fully insert the cable into the barrel of the connector.

4.  Continue to pump the tool handle and completely crimp the connector. These tools 

all have a built in by-pass cartridge that will automatically activate when full pressure 
is reached. There will be a notice-able decrease in handle pressure when the by-pass 
is reached. a high pitched squeaking sound is normal when the tool is operating in the 
high pressure stage.

5.  To release the tool, lift pump handle out and rotate clockwise until handle stops. With 

handle twisted, push down so the pin on the handle contacts the release pin on the 
tool body. The ram will retract and the tool is ready to begin its next cycle. In the event 
the tool will not release due to excess flash, hold release pin down with handle and pry 
tool jaws apart.

6.  A compression gauge, model PG-4 is available for the EP-410 for checking output pres-

sure. Consult factory for proper adjusting procedure.

Summary of Contents for CN-258

Page 1: ...L CN 258 CN 258 6 Ton Compression Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Height...

Page 2: ...bution markets Huskie Tools products represents the state of the art tools and are dependable safe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie...

Page 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Page 4: ...ye protection when operating this tool Failure to wear eye protection could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using th...

Page 5: ...ng system saves compression strokes and time The nest dies are D 3 and can be changed with other Kearney O type dies If you wish to use Burndy W type dies simply slip the W type over the D 3 nest die...

Page 6: ...rating the tool 3 Position the connector between the dies and pump tool handle until the connector is held in place Fully insert the cable into the barrel of the connector 4 Continue to pump the tool...

Page 7: ...efore use 1 Never operate tools without dies in place Failure to insert dies before operation will cause damage to the C frame and tool ram 2 Never attempt to adjust pressure setting without the use o...

Page 8: ...www spartacogroup com 800 860 6170 8 BREAKDOWN...

Page 9: ...dge C60 13 1 27 S 9 O Ring 410 71 1 28 P 7 O Ring C P C60 14 1 29 Valve Screw 1 300 11 2 30 Spring 227 300 31 2 31 Spring Holder 300 32 2 32 3 16 Ball 16 49 3 33 Spring 164 85A 07 1 34 1 8 Ball 40 20...

Page 10: ...www spartacogroup com 800 860 6170 10 NOTES...

Page 11: ...www spartacogroup com 800 860 6170 11 NOTES...

Page 12: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Reviews: