Inst331 Filtrite PZ Pool & Spa Pump V06_14
9
OPERATION OF CONTROL PANEL – PZ300 FILTRITE PUMP
Using the pumps in built timer to operate pump with a Filtrite Chlorinator
Factory Default Setting
1. The inbuilt timers are activated and will control the time the pump operates
2. Connectivity to Filtrite compliant Salt Chlorinators, is turned “off”
3. Use the
“auto” button to turn the pump on or off. When in on position, the pump will remain off until
the next timer period unless pressed again to manually on. If pump is turned to manually on, it will
continue to operate indefinitely. If in the “Off” position (visible on the LCD), the pump will remain
indefinitely off. For timer operation, ensure the “auto” button is pressed so that the LCD screen displays
“auto”.
Setting the current Time
1. If connected to a compliant Filtrite Salt Chlorinator, connect data cable between rear of pump and the
chlorinator.
2. Connect and turn power on to the pump and chlorinator
3. Toggle “menu” (twice) until “CLK” appears and press “enter” to set time. Use
up and down
arrows to
set the hour, press “enter” again to set minutes and then press “enter” again to set AM or PM.
4. Press
“enter” to accept
5. The LCD screen will quickly flash 3 times to indicate the new setting has been accepted.
Setting pump to operate independently of external Filtrite Compliant Chlorinator
1. Toggle Menu until “CONF” is displayed on the LCD screen
2. Press and HOLD “enter” for 3 seconds. “TMRS” will appear.
3. Press “enter”
4. Press UP or Down buttons to turn “TMRS ON”
5. Press “enter” to accept
6. Press
“auto” to return to main menu.
Changing Low, Med and High Speed Settings
1. Select the Speed Button to be adjusted, Low, Medium or High. Respective LED will light up.
2. Alter the speed in increments of 25 RPM using the up and down arrows until the desired speed is
displayed on the screen. Respective “Speed 1”, Speed 2” or “Speed 3”, will flash while editing.
3. The new speed will automatically save after 2 seconds. Flashing will stop to signal save.
Setting filtration timer periods
1. Press Menu to go to PRIM setting.
2. Prime period is defaulted to 5 minutes and high speed. We recommend if your pump is installed at or
below water level, you change the PRIM to 2 minutes. Press “enter” and then Up or Down arrows to
change the prime speed. Press “enter” to accept. Priming period will now be displayed.
3. Use the Up or Down arrow to change the Priming period. Press “enter” to accept.
4. Press Menu to go to TMR “timer settings” and press “enter” to change.
5. Timer 1 is factory set to start at 8 am. Use up or down arrows to change. Press High, Medium, or Low to
select the speed of the pump during Timer 1. On the LCD Screen High is represented by speed “1”,
medium by speed “2”, and Low by speed “3”.
6. Press Enter to move to the stop or end time of Timer 1. Use the up and down arrows to change the end of
Timer 1.
7. Timer 2 will now appear on the LCD Screen. Repeat instructions 4. to 6. Above.
8. Timer 3 will now appear but is factory preset to OFF. Moving any timer to midnight will turn that Timer
period off. Use the up and down arrows to activate the time and repeat process 4 and 5 above.
9. Timer 4 is also factory preset to “off” but can be activated by using the up and down arrows.
10. Remember to select the speed you wish to operate during each timer period by pressing the High, Medium
or Low buttons while still in the Timer Start program.