Inst331 Filtrite PZ Pool & Spa Pump V06_14
10
Using the in built pump timers with a non-compliant chlorinator or dosing unit.
1. We do not recommend the use of the pump timers when a non-compliant chlorinator or chemical doser is
supplied water flow by the Filtrite pump.
2. In this case, the pump operating hours should be controlled by the chlorinator time clock and the pump
plugged into the chlorinator. This is a safety measure provided for by most chlorinator manufacturers.
3. However, it is important to deactivate the inbuilt pump timers.
4. Toggle Menu until “CONF” is displayed on the LCD screen
5. Press and HOLD “enter” for 3 seconds
6. Toggle Menu until “TMR” appears.
7. Press UP or Down buttons to turn “TMR OFF”
8. Press “enter” to accept
9. Press
“auto” to return to main menu.
10. When cycling through the Menu button TMR will no longer appear
11. You will no longer be able to automatically have the speed of the pump changed during different times opf
the day.
12. However, if you wish for a period where the pump operates at a high speed, for example to circulate the
water vigorously for a part of the daily filtration, you can use the PRIMING setting to do so.
Using the PRIMING program to circulate the water at a higher flow rate for part of the daily filtration cycle.
1. Toggle Menu to go to PRIM setting.
2. Prime period is defaulted to 5 minutes and high speed. Use the up and down arrows to change the
Priming period up to 120 minutes. Use the High, medium, or low buttons to select the speed you wish the
pump to operate for during the Priming period. In this case, we recommend the High Speed button be
selected.
3. Press “Auto” to exit the programming.
Using pump with a Filtrite compliant external control
Filtrite Salt Chlorinators can control both the operating times of the Filtrite pumps PLUS the speed the pump
operates at during each timer period.
For the pump you must enable the communication port and disable the Pump in built timers.
1. Toggle Menu until CONF (configure) appears. Hold enter for 3 seconds.
2. Toggle Menu until “TMR” appears.
3. Press UP or Down buttons to turn “TMR OFF”. Remember, you are now using the external control to set
the pump operating hours, so the pump timer must be turned off.
4. Press “enter” to accept
5. Toggle menu until SYS (system) appears. Press the
up or down
button and turn to “ON”. The pump
will accept the start, end and pump speed instructions from the Filtrite compliant control chlorinator.
6. Press
“auto” to return to main menu.
7. The time will still be visible on the LCD display however, the timer function in the menu setting will no
longer appear. Toggle the menu button will now only display PRIM (priming program), CLK (clock setting)
and CONF (Configuration menu).
8. Refer to your Filtrite compliant Chlorinator manual for details of programming the pump speed and
operating hours.
Fault Codes
Fault Code (displayed on screen)
Meaning
HI T
Over Temperature
HI A
Over Current
Lo V*
Under Input Voltage
BSUC
Motor is Stuck
*Please note: It is normal for the “Lo V” fault code to display briefly on start up.