APFC POWER

2.3 Output protection
If the power supply is latch into shutdown stage (when OCP ,OVP or short protection 
is working ),the power supply shall return to normal operation only after the fault has 
been removed and remote signal must reset for a minimum of 1 second (or the AC 
removed for 10 second) . Then, it will turn on again.

2.3.1

 

Over

 

voltage

 

Protection

 (

OVP

)

In case of over voltage

 

limits

 

are

 

exceeded

the

 

power

 

supply

 

shall

 

provide

 

latch

-

mode

 

over

-

voltage

 

protection

2.3.2

 

Short

 

Circuit Protection (SCP)

An output short circuit is defined as any output impedance of less than 0.1 ohms. The 
power supply shall shut down and latch off for shorting all output to GND.

2.3.3

 

Over

 

Current

 

Protection

 (

OCP

)

Overload currents are applied to each tested output rail. If the current limits are exceeded, 
the power supply shall shutdown and latch off.