Station.Wire.(Red.Leads)
Common.Wire.(Black.Leads)
Leads.are.provided.to.attach.a.Hunter.DC.latching.
solenoid.or.other.two-wire,.low-voltage.latching.solenoids.
to.the.WVC..(Hunter.DC.latching.solenoid.part.#458200)
Hunter.DC.latching.solenoids.have.two.leads:.one.colored.
black.and.the.other.red.
To connect DC latching solenoids:
1.. Select.the.appropriate.station.wire.(red.wire).on.the.
WVC.Note:.Station.numbers.are.identified.on.top.of.
the.WVC..Strip.away.½".(13mm).of.insulation.from.the.
station.wire.
2.. Remove.½".(13mm).of.insulation.from.the.common.
wire.(black.wire).on.the.WVC.
3.. Twist.the.red.and.black.leads.from.the.solenoid.to.the.
red.and.black.leads.on.the.WVC.as.shown.in.the.figure.
4.. Make.sure.that.waterproof.connectors.are.used.to.
secure.all.wire.connections.
NOTE: The maximum recommended
distance from the WVC to any Hunter DC
latching solenoid is approximately 100
feet with 18 gauge wire. Long distances
between the WVC and the DC latching sole-
noid will reduce overall 9-volt battery life.
NOTE: The black wire from each solenoid
must be wired to the single black lead on
the WVC controller.
WIrIng dC laTChIng solenoIds To The WVC ....................................