background image

3

®

W

RH

G

RC

x

RH

x

RC

x

G

Y

x

x

RH, R, VR or4
24 Volt

RC, VC
24 Volt Cool

G or F
Fan

Y, C or M
Air Conditioning
Compressor

W or H
Heating

If the code letter on your
existing thermostat is

then mark the wire
with label shown

and connect to thermostat
terminal shown

Y

W

W

Y

Rh

Rc

G

Position wallplate on wall and pull existing wires through large opening. Then level for ap-
pearance. Mark holes for plastic anchors provided, if your existing holes do not line up with
those on the Hunter wallplate.

Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.

Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws
provided into wall anchor and tighten. See Figure 3.

NOTE: 5-wire Systems

If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave the jumper
wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and
RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.

Connect Wires and Mount Thermostat to Wallplate

Match and connect the labeled wires to the appropriate coded terminal screws on the
wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not con-
nected to the old thermostat.

Refer to the Wiring Diagrams below to be sure your system is wired correctly.

Be sure to tighten the terminal screws securely, otherwise a loose wire could cause opera-
tional problems with your system or thermostat.

Push excess wire back into the hole to prevent interference when installing the thermostat to
the wallplate.

Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.

Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate.
Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. 

(NOTE:

Do not force the thermostat onto the wallplate, as the terminal pins may be
damaged. If it does not snap properly, the thermostat may not work.)

 Insert the two AA size alkaline batteries, observing the polarity marked inside the battery

compartment.

 Switch on the main power at the panel or furnace.

Figure 4

Figure 5

Wire Labeling 

(Continued)

After labeling wires, disconnect them from the existing thermostat terminals.

Remove existing wallplate. To make sure wires do not fall back into wall opening, you may
want to tape them to the wall.

If hole in wall is larger than necessary for wires, seal this hole with insulating material so that
no hot or cold air can enter the back of the thermostat from the wall. This air could cause a
false thermostat reading.

Table A

NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on
this thermostat. Tape up the wire and do not use. This wire provides electricity to non-
battery powered thermostats.

Mount Wallplate and Thermostat

Remove the wallplate from your thermostat by pressing the release tab on the bottom of the
thermostat.  See Figure 2.

Figure 2

Figure 3

G Rc Rh Y

W

x

RH

Figure 6

Summary of Contents for Set & Save 47110A

Page 1: ...Model 47110A M AM 4 TEMP Programmable Thermostat Owners Manual ...

Page 2: ...Heat Cool and Off Fan Switch Fan switch forAutomatic or Continuous fan operation Battery Compartment Front access allows easy insertion of two AA 1 5V batteries Reset Press with a paper clip to reset the thermostat and return to power up settings Front Door Covers keys when not used for neat appearance Open by lifting from the bottom Up and Down Keys Keys for changing the Temperature setting Also ...

Page 3: ...rwise a loose wire could cause opera tional problems with your system or thermostat Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate Make sure the System Switch is set to OFF and the Fan Switch is set to AUTO Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate Press the top of the thermostat body to sn...

Page 4: ... position is for gas and most other systems HE position is for certain electric systems having a fan relay Auto Recovery selector DISABLE ENABLE Your thermostat is set from the factory with the Auto Recovery Feature enabled which com plies with the EPA ENERGY STAR Program If you prefer to use normal recovery slide the switch to the DISABLE position Figure 7 C F Selection Celcius Fahrenheit Your th...

Page 5: ...e Time Time Friday Temp Temp Temp Temp Saturday Time Time Time Time Sunday Temp Temp Temp Temp SA PM 2 TEMP day time hold return or SA PM 2 TEMP system cool heat off Revising Programs Familiarize yourself with manually changing programs so that you can easily modify the programs as your comfort needs change Follow the steps below to change the program times and temperatures NOTE 1 The program time...

Page 6: ...been in use To maximize your system s performance and energy efficiency change or clean your filter regularly When the total system runtime for heat and cool reaches 400 hours the Filter Change Indicator will flash as a reminder to check your system s filter After changing or cleaning the system s filter press and hold the Filter Key for 3 seconds The display will blink and the timer will be reset...

Page 7: ...replaced them Next use a paper clip to press the RESET button next to the keypad You will need to reprogram your thermostat and confirm normal operation If Error Mode returns please call Hunter Technical support at 1 866 268 1936 for further information Auto Cut Off Your thermostat will automatically cut off in Heat mode if the room temperature rises above 35 C 95 F It will cut off in Cool mode if...

Reviews: