background image

41960-01

10

Air Purifier Maintenance

6. Install the grill back onto the unit. First, line up the tabs on the bottom of the grill

with the openings on the purifier base and then push the top of the grill forward
until it is closed.

7. Plug in the air purifier. NOTE: This unit will not operate unless the grill is in the

correct position.

8. Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET

key for 2 seconds. The Pre-Filter Counter will return to 100% and the Pre-
Filter indicator will stop flashing.

Changing the Filter

When the filter exceeds 8000 hours (approximately 1 year of use), the Filter Life Counter
will display 0% life remaining and the Filter indicator will flash (refer to Filter Life Counters
for additional information, pg. 7). This is a reminder that you should check the filter and
replace if necessary. The proper time to change the filter depends on usage and the environ-
ment. Use the following list to help determine if the filter should be changed:

• Compare the color of the filter to the color coded chart on the inside of the housing. If the

filter color matches the darkest color on the chart, you should replace the filter.

• If you notice a decrease in air output or an increase in noise at any time during normal

operation, the filter may be clogged. Replace the filter to return to normal operation.

To change the filter and reset the Filter Life Counter:

1. First, turn off and unplug the air purifier.

2. Next, remove the front grill. Place your fingers in the recesses on either side of the

top of the grill and pull firmly.

3. Gently pull on the filter to remove it from the unit. While removing the filter,

note the directional arrows printed on the side of the filter. The new filter will be
installed with the same orientation. Once removed, the used filter can be dis-
carded.

4. Remove the new filter from its wrapping and look at the directional arrows

printed on the side of the filter. Install the filter with arrows pointing towards
the unit. Press the filter firmly into the air purifier. To avoid damaging the
filter media, you should press on the frame of the filter only.

5. Reinstall the grill by first lining up the tabs on the bottom of the grill with the

openings on the air purifier base and then pushing the top of the grill forward
until it is closed.

41960-01_rev 1-13-06.pmd

1/13/06, 4:50 PM

10

Summary of Contents for QuietFLO 30525

Page 1: ...Air Purifier www hunterfan com 41960 01 01 13 2006 2006 Hunter Fan Company Replacement Filter Information Pre Filter 30901 HEPA Filter 30940 Model 30525 Model 30525 41960 01_rev 1 13 06 pmd 1 13 06 4 50 PM 1 ...

Page 2: ...eration Initial Operation 6 Filter Life Counters 7 Programming Locking Unlocking the Keypad 8 Resetting the Air Purifier 8 Air Purifier Maintenance Cleaning Your Air Purifier 9 Changing the Pre Filter 9 Changing the Filter 10 Obtaining Replacement Filters 11 Troubleshooting Problems and Solutions 12 Technical Support 12 Warranty Information 13 41960 01_rev 1 13 06 pmd 1 13 06 4 50 PM 2 ...

Page 3: ...water at any time because permanent damage will occur To properly clean your air purifier follow the instructions in the Maintenance section of this manual pg 9 READ AND SAVE ALL INSTRUCTIONS Introduction Thank you for purchasing the QuietFlo HEPA Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to improve the quali...

Page 4: ...maller particles are collected Finally the clean purified air is released back into the room Air Purifier Components Fig 1 Illustration of the Air Filtration System Fig 2 Air Purifier Components Fig 3 Inside Surface of Front Grill Dust Irritants Pollen Allergens Odors Bacteria Pet Hair Dander Carbon Pre Filter True HEPA Filter 99 97 3 Microns HOOK TAPE GRILL VENTS HOOK TAPE HEPA FILTER PRE FILTER ...

Page 5: ...d turns the unit on and off PRE FILTER RESET Resets the Carbon Pre Filter Life Counter FILTER RESET Resets the HEPA Filter Life Counter Fig 4 Air Purifier Control Area and Alpha numeric Display ANIMATED BLOWER HEPA FILTER LIFE COUNTER KEYPAD LOCKED INDICATOR BLOWER SPEED CARBON PRE FILTER INDICATOR HEPA FILTER INDICATOR PRE FILTER LIFE COUNTER 41960 01_rev 1 13 06 pmd 1 13 06 4 50 PM 5 ...

Page 6: ...45º You can remove the front grill by placing your fingers under the handle and pulling the front grill towards you and then up Fig 5 Fig 6 PULL FORWARD THEN UP HANDLE 3 Next check the HEPA filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 The carbon pre filter is mounted inside the front grill with hook tape Confirm that it p...

Page 7: ...r filter has left Although the exact life of the filters de pends on the environment the table below gives typical usage times of the filters Table 2 Typical Usage Times of the Filters Fig 7 The display shows the percentage of life left since the counter was reset NOTE The per centage level drops in 5 increments The values of the Pre Filter and Filter Life Counters are stored in the air purifier s...

Page 8: ... Refer to Fig 8 After releasing the keys the Keypad Locked Indicator will dis appear 2 To unlock the key pad press and hold the UP DOWN keys simultaneously for 2 3 seconds The Keypad Indi cator will disappear and the keypad will be functional Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the air purifier If you...

Page 9: ...minder that you should replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 2000 hours approximately 3 months of use If necessary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of the HEPA filter Refer to Obtaining Replacement Filters pg 11 if you need he...

Page 10: ...If the filter color matches the darkest color on the chart you should replace the filter If you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Replace the filter to return to normal operation To change the filter and reset the Filter Life Counter 1 First turn off and unplug the air purifier 2 Next remove the front grill Place y...

Page 11: ... number by looking at the information label on the back of the air purifier The model number will be listed on the label Then call 1 800 4HUNTER for your nearest retailer or Hunter Customer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To or der online visit our Website at www hunterfan com To ensure that you obtain the cor rect filters please find your model number below that spe...

Page 12: ...t is plugged in Check the installation of the front grill Reset the air purifier See Resetting the Air Purifier on pg 8 Key pad has been locked to prevent accidental changes to the programs See Keypad Lock on pg 8 to unlock the key pad Reset the air purifier See Resetting the Air Purifier on pg 8 The Filter and or Pre Filter Life Counters have reached the estimated usage times Check and replace fi...

Page 13: ...ARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DU RATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE I...

Page 14: ...CT INDI RECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE AIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCI DENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MA...

Page 15: ...ww hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 41960 01 Printed in China and Taiwan M AM 4 TEMP 41960 01_rev 1 13 06 pmd 1 13 06 4 51 PM 15 ...

Reviews: