1. Remove the seat cushion.
2. Remove dust and corrosive substances from the
battery surface.
3. Replace the terminal clamp when it is severely
corroded.
Note: When disassembling the battery, first remove the
negative terminal clamp (-) and then remove the positive
terminale clamp (+). When installing, first install the
positive (+), then install the negative (-), be sure to avoid
the positive terminal (+ ) contact with the motorcycle
chassis.
Ensure that the terminal clamps are secured tightly.
The battery is filled with sulfuric acid, and it causes
serious damage if it comes into contact with the eyes and
skin. It should be washed immediately, rinse it with water
for 5 minutes and seek medical attention immediately
.
Battery
Set the ignition switch to the "OFF" position when
replacing. Please use the main fuse of the specified
specifications: (30A).
Install the fuse in the fuse box correctly.
If a new fuse blows (burns) immediately after the fuse is
installed, it indicates that there is a fault or short circuit
in the electrical system. Please consult with your Hunter
dealer.
Do not use higher rated fuses (30A) or attempt to
replace a fuse using wire or any other material. This can
cause serious damage to the motorcycle or cause a fire..
Avoid water entering the battery area when washing the
motorcycle.
28
Battery maintenance
Main Fuse replacement